3 Product specific safety notices
WARNING
Fault in escape door function due to unsuitable closing cylinder or un-
suitable environment
The use of unsuitable closing cylinders or components that are not opera-
tional can adversely affect the function of an escape door. If you use the
anti-panic cylinder in locks that are not approved, the escape door function
can be disrupted and not released again. Contact SimonsVoss Technolo-
gies GmbHfor further information.
1. Ensure that all parts of the lock are operational.
2. Check that the panic function of the mortice lock is ensured.
3. Only use the anti-panic cylinder in locks that are expressly approved for
the anti-panic cylinder. See also the manufacturer's documentation in
this respect.
4. Do not use the anti-panic cylinder in temperatures below -20 °C or
above +50 °C.
5. Carry out a function test of the anti-panic cylinder after installation or
after a battery change.
CAUTION
Use of the anti-panic version of the locking cylinder in non-approved
locks
If you use the anti-panic version of the locking cylinder in unauthorised
locks, the escape door function may be impaired and cannot be released
again.
1. Only use the anti-panic version of the locking cylinder in locks for which
the locking cylinder is expressly approved.
2. Please refer to the documentation of the respective lock manufacturer.
3. Contact SimonsVoss Technologies GmbH for further information on this
).
Digital Locking Cylinder 3061
(Manual)
3. Product specific safety notices
10 / 54