10. Replace the thumb-turn (align the triangle mark as in the diagram),
hold the recessed grip ring firmly and fasten the inside thumb-turn by
turning in a clockwise direction (about 10°). (Diagram may differ slightly
from the purchased product)
11. Push recessed grip ring back onto the thumb-turn, so that the thumb-
turn and ring close together in a flush fit.
12. Place the installation/battery key on the inside thumb-turn in such a
way that the two teeth lock into the openings in the locking disc; if ne-
cessary, turn the thumb-turn until both teeth engage into the locking
disc.
13. Close the thumb-turn again by turning it about 30° in a clockwise direc-
tion (until you hear a click).
Then activate an authorised ID medium and check that it functions.
8.5 Procedure for outer thumb turn (MH cylinder)
4 batteries are built into the MH cylinder: 2 in the inside thumb-turn, 2 in the
outer thumb-turn.
Proceed as follows to replace the two batteries:
1. Use the battery replacement key to detach the outer thumb-turn. To do
so, face the outer thumb-turn and place the battery replacement key on
the bayonet mount and turn in a clockwise direction until you can re-
move the thumb-turn easily.
9
The outer thumb-turn is now fully detached.
2. Place the battery replacement key on the detached thumb-turn again
and open the bayonet mount completely
( turn in an anti-clockwise dir-
ection as you face the mount)
. You may be able to skip this step.
9
The lid springs open by itself as the bayonet mount is unscrewed.
3. Carefully lift off the lid.
9
The lid is attached to the thumb-turn with a small securing strap and
a ribbon cable; the batteries are now exposed.
4. Insert new batteries in such a way that the two plus poles lie flat on one
another and then position in the thumb-turn.
NOTE
You should always replace both batteries with new ones when changing
the batteries.
Digital Locking Cylinder 3061
(Manual)
8. System 3060 battery replacement
41 / 54