12 Technical data
Radio emissions
SRD (depending on
equipment)
24.50 kHz - 25.06 kHz
-20 dBµA/m (10 m dis-
tance)
RFID (depending on
equipment)
13.564 MHz - 13.564
MHz
-19.57 dBµA/m (10 m
distance)
SRD (WaveNet) (de-
pending on equipment)
868.000 MHz -
868.600 MHz
<25 mW ERP
There are no geographical restrictions within the EU.
12.1 Locking cylinder
Profile cylinder
Basic length:
Outside 30 mm, internal 30 mm
(AP/WP 35mm)
Installation lengths in 5 mm increments, overall length up to 140 mm (max.
90 mm on one side); special lengths on request.
Batteries
Type:
CR, 2450, 3 V
Manufacturer:
Murata, Panasonic, Varta
Quantity:
2 units
Battery life:
up to 300,000 lock operations or up
to 10 years on standby
Ambient conditions
Operating temperature:
-25°C to +65°C
Storage temperature:
-35°C to +65°C
Protection class:
Standard protection rating IP54
(when installed); .WP variant: IP66
Air humidity:
<95%: non-condensing
Features
3,000 access events can be logged (ZK)
Network-ready with integrated LockNode (WN)
LockNode can be retrofitted
Time zone groups: G1: 5 / G2: 100
Max. number of transponders per G1 Cylinder: 8000 / G2: 64,000
Digital Locking Cylinder 3061
(Manual)
12. Technical data
47 / 54