3.

 

Handling 

Der sIMPLEk-Stick includes 2 operation modes: 

[1] tuning-mode 

[2] calibration-mode 

A change from Tuning Mode to Calibration Mode is made by plugging the sIMPLEk into any active USB 

port for at least 5 seconds. The next time you plug in the sIMPLEk-Stick on the e-bike, the calibration mode 

starts directly. 

A calibration is necessary once, so that for each wheel circumference the actual speed in the tuning mode 

is readable. 

The tuning mode allows unlimited engine support (theoretically up to 100 

 (mph)).

 

 

 

Summary of Contents for Stick Pro

Page 1: ...sIMPLEk Stick Pro Tuningdongle operation manual ...

Page 2: ...tion and safety instructions carefully sIMPLEk Stick Pro Tuningdongle 1 General remarks and savety instructions 2 Installation 2 1 Bosch Classic 2 2 Bosch Active and Performance Line 2 3 Yamaha 2 4 Brose 3 Handling 3 1 Tuningmode 3 2 Calibrationmode ...

Page 3: ...ed for the use of tuning measures without further technical adjustments The use leads to the warranty loss of the e bike If the e bike concerned has an operating license it will be extinguished Please put on a suitable helmet at all times The usage of the assembly set leads to the loss of warranty concerning the vehicle Regarding the installation of the E Bike please make sure not to damage any ca...

Page 4: ...r can be removed If necessary pull the plug speed sensor with a flat nose pliers Fig 3 Now close the industrial plug of the connection cable at the position of the previously unplugged speed sensor The supplied rubber tube has to be put off the plug of the speed sensor until the sealing blades Afterwards the speed sensor and the pin connector of the connection cable have to be connected Fig 4 The ...

Page 5: ... screws with a socket Fig Now the engine cover can be removed If necessary pull the plug speed sensor with a flat nose pliers Fig 8 Now close the industrial plug of the connection cable at the position of the previously unplugged speed sensor The supplied rubber tube has to be put off the plug of the speed sensor until the sealing blades Afterwards the speed sensor and the pin connector of the con...

Page 6: ...ssible until the motor can be swung out of the frame Fig 12 Now you can see the plug connections Disconnect the connector of the speed sensor by pressing the detent with the small screwdriver Now close the sIMPLEk between motor and speed sensor Ensure that the connectors are correctly seated audible clicking noise when snapping into place Then the motor can be fixed in the frame again and all scre...

Page 7: ...ine cover can be removed If necessary pull the plug speed sensor with a flat nose pliers Fig 15 Now cut through the cable of the speed sensor in order to be able to connect the wires to the terminal block Insert the cable ends into the terminal block Observe the label on the terminal block for correct polarity Fig 16 The cables are fixed by pressing on the insulation displacement terminal Fig 17 L...

Page 8: ...ging the sIMPLEk into any active USB port for at least 5 seconds The next time you plug in the sIMPLEk Stick on the e bike the calibration mode starts directly A calibration is necessary once so that for each wheel circumference the actual speed in the tuning mode is readable The tuning mode allows unlimited engine support theoretically up to 100 mph ...

Page 9: ...l the route will be caught up As soon as the difference will be balanced the speedometer displays 0 0 mph again and the E Bike switches off itself independently If the E Bike will be switched off in advance sIMPLEk Stick stores the difference with an accuracy of 200m and catches up the route later on Thus the maximal speed as well as the actually travelled route total distance will be reproduced c...

Page 10: ...Stick as closely as possible at 10 0 mph If you insert the stick again precised calibration will be start You can see the speed on the speedometer which comes closer in small steps to 10 0 mph and can fall in the meantime repeatedly to 0 0 mph As soon as the 10 0 mph will be displayed for the first time again remove the sIMPLEk Stick Thus the calibration is completed Carry out calibration again In...

Page 11: ...of with household waste Warranty Insofar as the device was purchased as a consumer within the EU the respective transposition of Directive 2011 83 EU into national law with regard to the minimum standard of warranty applies In countries outside the EU the respective valid minimum warranty claims apply ...

Reviews: