Instruction Manual
www.tksimplex.com
Hydraulic Cable Cutter – HCCP3000
www.tksimplex.com
4
4.
MAINTENANCE
1.
After use, the tool should be cleaned. Lubricate the area where the blade comes into contact with the head.
2.
Ensure all fasteners are securely fastened.
3.
In the event of oil leaks or improper functioning, contact your nearest SIMPLEX authorized service center for inspection
and repair.
CHANGING THE BLADE
Note:
Refer to Section 6 of this manual for parts list and item numbers. To help prevent damage to the tool, always
perform blade replacement procedures in a clean and dry work area.
Pump the handle until the blade moves out far enough to provide access to the blade retaining screw (17). Remove the
screw (17) and remove the old blade. Mount a new blade and check that the orientation is correct (see diagram, below).
Apply Loctite 242 thread sealant to threads of screw (17). Reinstall the screw (17) and tighten it to a torque of 531-620 in-
lb [720-841 Nm]. Retract the blade after completing blade replacement procedures.
5.
ADDITIONAL INFORMATION
All information, illustrations and specifications in this operation manual are based on the latest information available at the time of
publication. The right is reserved to make changes at any time without notice.
Equipment operators and installers shall be responsible for ensuring that a safe working environment and safe systems of work are
in place before operating the equipment.
Simplex declares that this product has been tested and conforms to applicable standards and complies with all CE requirements.
OK
OK
Summary of Contents for HCCP3000
Page 8: ......