background image

OPTION 1: base on grass 

OPTION 2: base on slabs 

OPTION 3: base on concrete 

OPTION 4: no base on brick 

 

A (mm)  B (mm) 

 
 
 

3150 

10’4” x 6’3” 

1910 

10’4” x 8’3” 

2530 

10’4” x 10’4” 

3150 

10’4” x 12’4” 

3770 

Summary of Contents for 10 LE Series

Page 1: ...A mm B mm 3150 10 4 x 6 3 1910 10 4 x 8 3 2530 10 4 x 10 4 3150 10 4 x 12 4 3770 R A N G E ...

Page 2: ...ecting a site for your greenhouse it is vital that you choose as flat and level an area as possible A concrete or slabbed base will provide the most solid foundation for your greenhouse IMPORTANT Do not fix your building down until the building is fully assembled including glazing Avoid placing your greenhouse under trees or in other vulnerable locations To minimise the risk of wind damage try to ...

Page 3: ...OPTION 1 base on grass OPTION 2 base on slabs OPTION 3 base on concrete OPTION 4 no base on brick A mm B mm 3150 10 4 x 6 3 1910 10 4 x 8 3 2530 10 4 x 10 4 3150 10 4 x 12 4 3770 ...

Page 4: ...4 183 3096 1 2 4 10 2488 1 300 n a 12 14 16 18 1 3720 2 5 3100 2 17 2480 2 25 1860 2 3 3720 2 8 3100 2 14 2480 2 27 1860 2 49 1314 4 32 1210 4 6 8 10 2 3720 1 6 3100 1 12 2480 1 26 1860 1 188 1866 4 6 8 10 187 1920 4 93 636 1 2 3 4 601 608 4 6 8 10 602 900 2 3 4 5 184 3096 1 36 1857 2 38 2 70 1538 2 71 2 186 2269 1 191 480 1 189 1855 2 190 2 30 1210 2 31 2 ...

Page 5: ...10 8 10 10 10 12 10mm M4 M6 121 612 1 2 3 4 123 612 1 2 3 4 124 610 2 4 6 8 1 2 3 4 2 4 6 8 6 12 18 24 2 4 6 8 130 619 41 a 1763 1 41 1763 3 95 614 2 137 883 4 4 4 4 4000 1 8 167 300 380 2 2 2 234 266 298 330 108 126 144 162 6 roll 7 roll 8 roll 9 roll 161 173 185 197 171 185 199 213 8 M6 CROP M6 M6 ...

Page 6: ...M6 28 Part No mm Quantity 14 2480 2 32 1210 6 17 2480 2 49 1314 4 M6 22 M6 22 Part No mm Quantity 27 1860 2 32 1210 4 25 1860 2 49 1314 4 M6 16 M6 16 Part No mm Quantity 3 3720 2 32 1210 10 1 3720 2 49 1314 4 M6 34 M6 34 6 8 10 12 27 25 14 17 8 5 3 1 X 2 X 2 X 2 X 2 ...

Page 7: ...49 32 32 ...

Page 8: ... 36 1857 1 38 1857 1 51 1480 2 70 1538 1 Part No mm Quantity 71 1538 1 136 924 2 184 3096 1 189 1855 1 190 1855 1 191 480 1 38 38 M6 2 1 184 36 38 51 30 31 136 189 190 136 51 70 71 136 51 191 This bar is currently riveted to the door track assembly 10 ...

Page 9: ...184 51 36 38 184 30 31 189 190 51 136 30 31 189 190 191 36 38 189 190 10 10 161 This bar is currently riveted to the door track assembly 10 ...

Page 10: ...1210 1 31 1210 1 36 1857 1 38 1857 1 51 1480 2 70 1538 1 71 1538 1 183 3096 1 185 3076 1 Part No mm Quantity 186 2269 1 189 1855 1 190 1855 1 197 2190 2 45 45 M6 2 1 183 36 38 51 30 31 189 190 185 51 70 71 186 197 197 51 185 ...

Page 11: ...36 38 189 190 183 30 31 183 51 36 38 185 189 190 186 189 190 30 31 51 185 197 189 190 ...

Page 12: ...This bar is currently riveted to the door track assembly 10 Please ignore at this stage Part 10 fitted in section 10 ...

Page 13: ... Drill centrally between two vertical glazing bars for neatness it is not essential to drill every section Make sure the bolt head does NOT interfere with the line of the glass Cills should be drilled 18mm from the inside vertical face to avoid the front glass face Do NOT anchor the structure to the ground until the end Packed with base M6 CROP ...

Page 14: ... No mm Quantity 12 2480 1 93 636 2 187 1920 4 188 1866 6 601 608 6 602 900 3 32 6 Part No mm Quantity 26 1860 1 93 636 1 187 1920 4 188 1866 4 601 608 4 602 900 2 22 1 2 1 2 3 4 4 188 3 187 187 188 188 187 49 ...

Page 15: ...12 Part No mm Quantity 2 3720 1 93 636 4 187 1920 4 188 1866 10 601 608 10 602 900 5 52 10 Part No mm Quantity 6 3100 1 93 636 3 187 1920 4 188 1866 8 601 608 8 602 900 4 42 X 2 M4 X 4 602 601 93 ...

Page 16: ...124 121 121 124 610 x 610 M6 10mm X 2 X 2 X 4 M4 X 2 M4 X 2 X 4 or OPTIONAL CAPPING X 1 1220mm Part No mm Quantity 121 612 1 123 612 1 124 610 2 ...

Page 17: ...123 610 x 610 ...

Page 18: ...Part No mm Quantity 41 1763 3 95 614 2 41a 1763 1 130 619 8 137 883 4 130 95 41 41a 41 41 130 95 130 137 137 130 130 130 FLUFF FLUFF M6 32 32 M6 X 4 X 2 7 6 m FLUFF 4 m X 4 X 4 ...

Page 19: ...41 41 41a 41 Please note that you may need to change the orientation of the diagonal flat bar braces in your door s to make fitting your door stop easier i e the diagonals can be fitted in either orientation FLUFF ...

Page 20: ......

Page 21: ... R 610 X 1280 6 8 10 12 A 610 X 610 12 14 16 18 G 457 X 1197 8 H 610 X 363 2 610mm 12 R S S S S A A R G G S A 610 x 610 1 D 610 x 153 1 L 573 x 100 5 A A H R G G X X Y z Y G G X X 30 X 340 457 457 Y 657 347 A A A H A A z S V V A A V 44 610 464 Z 610 80 495 ...

Page 22: ...10 X 610 28 34 40 46 B 610 X 457 28 32 36 40 C 610 X 386 6 8 10 12 H 610 X 363 2 P 457 X 87 4 D 610 x 153 1 L 573 x 100 5 D L A H E B B B B B B B B B X X P P 30 X 340 457 457 E 580 270 D 64 610 486 Z 610 80 495 E A D E A B A B B B X X P P A D A B A B B B Z A A H C C C C C ...

Page 23: ...123 85 93 85 93 85 93 85 93 ...

Page 24: ...oor rear and attach door stop handles see diagrams below Re attach the nuts Attach upper door track 10 to the two bolts left ready in section 2 with nuts position 10 vertically and push it through the central section between the two glaze bars Twist 10 so that the slots in the mounting bar are facing upwards Slide doors into upper track 10 and lower track 184 adjust the height of 10 until the door...

Page 25: ...SAND O7mm No 10 x 2 Please note you will have to drill and screw through your metal base and into your solid foundation at an angle from outside the building ...

Page 26: ...nice if we can include real greenhouse photos in the brochure so if you send us a photo of your greenhouse to us and it is good enough to get into our next brochure we will send you a 25 reward Please send your photos to Photo competition Simplicity Greenhouses Blythe Park Cresswell Stoke on Trent Staffs ST11 9RD 01782 398600 Or better still email us on sales simplicitygreenhouses co uk Please wri...

Page 27: ... is a good idea to use a transparent all weather silicone inside and outside of the building where there are any gaps Also the top of the vents can be siliconed Vent top corner siliconed along with bar capping Inside eave area siliconed ...

Page 28: ...900 2 3 4 5 1 2 3 4 6 7 8 9 4m 4m 4m 4m 1 smalls pack for correct size of building BOX PACKED BY No mm 6 8 10 12 1 3720 2 2 3720 1 3 3720 2 5 3100 2 6 3100 1 8 3100 2 10 2488 1 1 1 1 12 2480 1 14 2480 2 17 2480 2 25 1860 2 26 1860 1 27 1860 2 30 1210 2 2 2 2 31 1210 2 2 2 2 32 1210 4 6 8 10 36 1857 2 2 2 2 38 1857 2 2 2 2 41 1763 3 3 3 3 41a 1763 1 1 1 1 49 1314 4 4 4 4 51 1480 4 4 4 4 70 1538 2 2...

Reviews: