background image

SimpliFire •  Scion Trinity Floating Mantel Instruction Manual  •  2043-970  Rev. B  •  9/20

6

Figure 14

Figure 15

7.   Insert the four (4) wooden dowels into the open 

 

      holes of the bottom mantel.  See Figure 15.

6.   Secure the bottom mantel to the side brackets using  

      two (2) M6*16 screws.  See Figure 14.

M6*16 SCREWS

(2 EACH SIDE)

    SIDE

BRACKET

BOTTOM MANTEL

WOODEN DOWELS

    (2 EACH SIDE)

Figure 16

8.   Attach the mantel side panels to the bottom mantel  

      by aligning the holes in the mantel sides with the  

      dowels. See Figure 16.

MANTEL SIDE PANELS 

Figure 13

5.    Attach two (2) side brackets to the rear sides of the  

       appliance using four (4) ST4*8 screws.  See Figure   

       13.

SIDE 

BRACKET

BOTTOM MANTEL

ST4*8 SCREWS

(2 EACH SIDE)

Summary of Contents for Scion Trinity SF-SCT43-MANTEL

Page 1: ...ewdriver Safety glasses Flat blade screwdriver 1 2 in drill bit for 3 16 diameter toggle bolts applicable if installing on masonry walls Masonry drill bit 5 16 in applicable if installing on ma sonry walls Kit Components Mantel Bottom Mantel Top Mantel Side Panel 2 Side Bracket 2 Bottom Bracket 2 Front Bracket 1 ST4 12 Screws 6 ST4 8 Screw 4 ST6 50 Screw 8 M5 10 Screw 2 M6 16 Screws 8 6 30 Wooden ...

Page 2: ...ocation If applicable according to local electrical codes the floating mantel is able to conceal a horizontally install wall receptacle behind the bottom mantel section Refer to Figure 2 to assist in locating the final appliance and mantel location in reference to the receptacle and or on the wall mounting bracket Note The top of the floating mantel will be 24 inches 610mm from the bottom edge of ...

Page 3: ...o mount the mounting bracket is dif ferent between masonry walls and framed walls Refer to the following sections for more detail on the method applicable to this installation The toggle bolt anchors are provided to accomodate the required anchor points based on the appliance Use of toggle bolt anchors requires drywall thick ness of minimum 1 2 in and drilled holes size of 1 2 in diameter Insert t...

Page 4: ...pull down to ensure the hooks are fully engaged See Figure 8 4 Secure the appliance to the bracket with two M5X10 screws See Figure 8 1 2 Secure with screw on each side of appliance Figure 8 Attaching Appliance to Bracket Mounting Hooks Point Up Masonry Wall Locate the mounting bracket on the wall in the desired location of the appliance Level the bracket then mark its location on the wall includi...

Page 5: ...r and bottom 2 inch 51mm trim pieces provided with the appliance Note The bottom 2 inch trim has two extra holes as shown in Figure 9 Figure 9 SCREW LOCATION 2 inch 51 mm TOP MOUNTING TRIM MOUNTING HOLES MOUNTING HOLES Mantel Installation SIDE COVER PLATE both sides 2 inch 51 mm BOTTOM MOUNTING TRIM 2 inch 51 mm REAR TRIM INCLUDED WITH APPLIANCE 3 SCREWS Figure 11 3 Attach the front bracket to the...

Page 6: ...s using two 2 M6 16 screws See Figure 14 M6 16 SCREWS 2 EACH SIDE SIDE BRACKET BOTTOM MANTEL WOODEN DOWELS 2 EACH SIDE Figure 16 8 Attach the mantel side panels to the bottom mantel by aligning the holes in the mantel sides with the dowels See Figure 16 MANTEL SIDE PANELS Figure 13 5 Attach two 2 side brackets to the rear sides of the appliance using four 4 ST4 8 screws See Figure 13 SIDE BRACKET ...

Page 7: ...he mantel top with the dowels See Figure 18 MANTEL TOP 11 Secure the top mantel to the side brackets using two 2 M6 16 screws on each side See Figure 19 SimpliFire a brand of Hearth Home Technologies 7571 215th Street West Lakeville MN 55044 www hearthnhome com WOOD DOWELS Figure 20 Wall Mount Weight Capacity 100 LBS 45Kg The total weight of objects sitting on the mantel shelf must not exceed 100 ...