background image

SimpliFire  • SF-ALLP50-BK, SF-ALLP60-BK, SF-ALLP72-BK  •  2044-980 Rev. C  •  10/19

  

8

D.  Location

Note:  

If this unit is installed in a bathroom, it must be 

protected by GFCI receptacle or circuit.  If receptacle is 

used it must be readily accessible.  This electrical ap-

pliance is not water tight.  To prevent electrical shock, it 

must be installed as to prevent water from entering unit.  It  

must be installed away from showers, tubs, or other water 

sources.  Never locate the appliance where it may fall into 

a bathtub or other water container. 

 

When choosing a location for your fireplace ensure that 

the following general rules are followed:  
•  For best results, install out of direct sunlight.  
•  Power supply service must be installed within  

proximity of electric fireplace prior to finishing to 

avoid reconstruction. 

•  Appliance should be mounted so the front glass 

panel is located outside the swing arc of adjacent 

door.

•  See Figure 3.2 and 3.3 to determine location of ap-

pliance installation.

E.  Clearance to Combustibles 

Minimum Clearance to Combustible Construction

  Sides.......................0 in.
  Floor........................0 in.
  Top..........................0 in.
  Back........................0 in.
  Front..................... 36 in.
  Mantel...................5/8 in.
   

See Figure 3.2.  

F.  Electrical Supply Circuit Requirements

Plan the location of the appliance so that it will have ad-

equate electric power.  A 15 AMP, 120VAC/60Hz circuit 

is required.  Additional appliances on the same circuit as 

this appliance may exceed the current rating of that cir-

cuit.  A dedicated circuit is not required, but is strongly 

recommended to prevent circuit breaker trips or fuse 

failure.

min. 0 in.

min. 5/8 in.

Ceiling

Mantel

Floor

Wall

Outside 

swing arc 

of adjacent 

doors

min. 0 in.

min. 4 in.

Figure 3.2 Location and Clearances Requirements

ELECTRICAL

OUTLET

LOCATION

Figure 3.3 Electrical Outlet Location

Note:  

If mounting on a wall and using the supplied pow-

er cord, choose a location near an outlet so an extension 

cord is not required.  

WARNING! Risk of Fire! 

Keep electrical cords, drapery, 

furnishings or other combustibles at least 3 ft. (0.9 m) 

from the front of the electric fireplace, and away from the 

sides or rear.

24 in. 

MAX

4 in.

MIN.

UNLIMITED

TRIM RING

Maximum Combustible and

Non-Combustible Mantel 

Projections. 

Summary of Contents for SF-ALLP50-BK

Page 1: ...P72 BK READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE INSTALL OPERATE OR MAINTAIN THIS PRODUCT PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE Please contact your SimpliFire dealer with any questions or concerns For the location of your nearest SimpliFire dealer please visit www hearthnhome com...

Page 2: ...t malfunctions Disconnect power at service panel and have appliance inspected by a certified electrician before reusing Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the appliance To prevent a possible fire do not block appliance connection fan air intakes or exhaust in any manner A heater has hot and sparki...

Page 3: ...10 C Electrical Connection Installation 11 D Appliance Final Setup 12 5 OPERATING INSTRUCTIONS A Manual Switch Function 13 B Operating by Remote Control 14 C Room Temperature and Thermostat Function 15 D Resetting Temperature Cutoff Switch 15 6 MAINTENANCE A Maintenance 16 B Cleaning 16 C Servicing 16 D Service Parts List 17 E Contact Information 20 Safety Alert Key DANGER Indicates a hazardous si...

Page 4: ...es melted items or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes Repair or replacement of parts that are subject to normal wear and tear during the warranty period These parts include paint batteries and the discoloration of glass Damages resulting from 1 failure to install operate or maintain the appliance in accordance with the inst...

Page 5: ...n Follow these instructions carefully during the installation to ensure maximum safety and benefit This equipment uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful EMI to radio or television reception which can be determined by turning the equipment off and on The user is encouraged to try to correct the EMI by one or mo...

Page 6: ...r for power cord installation only Type NM B Wire Strain Relief B Tools and Supplies Needed Parts and Hardware List Part Quantity Appliance 1 Glass Panel 1 Instruction Manual 1 Remote Control 1 AAA Battery 2 Trim Shipped attached to appliance with ST4X8 x14 screws SF ALLP50 BK or x18 SF ALLP60 BK SF ALLP 72 BK 1 ST4X8 screw glass to appliance 2 Side Panel 2 ST4X40 Screws appliance to framing 4 Sma...

Page 7: ...ALLP50 BK in 52 5 16 20 7 16 48 15 50 1 2 19 3 8 5 5 8 mm 1329 519 1219 381 1283 492 143 SF ALLP60 BK in 62 5 16 20 7 16 58 15 60 1 2 19 3 8 5 5 8 mm 1583 519 1473 381 1537 492 143 SF ALLP72 BK in 74 5 16 20 7 16 70 15 72 1 2 19 3 8 5 5 8 mm 1888 519 1778 381 1842 492 143 D F G E B A C C Appliance Dimensions Including Front Trim ...

Page 8: ... E Clearance to Combustibles Minimum Clearance to Combustible Construction Sides 0 in Floor 0 in Top 0 in Back 0 in Front 36 in Mantel 5 8 in See Figure 3 2 F Electrical Supply Circuit Requirements Plan the location of the appliance so that it will have ad equate electric power A 15 AMP 120VAC 60Hz circuit is required Additional appliances on the same circuit as this appliance may exceed the curre...

Page 9: ... of the home to prevent cold air drafting prob lems The chase should not break the outside building envelope in any manner Walls ceiling baseplate and cantilever floor of the chase should be insulated Va por and air infiltration barriers should be installed in the chase as per regional codes for the rest of the home Additionally in regions where cold air infiltration may be an issue the inside sur...

Page 10: ...e is to be installed directly to the face of the wall refer to Section 4 C for installation B Recessed in 2 x 6 Framed Wall 1 Finish wall construction per requirements in Figure 4 1 Note This appliance is inteded for use with no more than 1 inch combined thickness of wallboard and finishing materials 2 Connect to electrical service Reference Section 4 D 3 Remove interior side panels on left and ri...

Page 11: ...cted and grounded in accordance with local building elec trical codes 1 Remove terminal block cover plate located on the right end of the appliance 2 Install a wire strain relief bushing into the cover plate 3 Terminate type NM B wire to the terminal block ensure connections are secure and tighten the strain relief Use 3 32 slotted heat screwdriver or equivalent to depress the spring loaded termin...

Page 12: ...the bottom edge into the channel behind the outer trim See Figure 4 12 Figure 4 12 Glass Front Installation CAUTION Two adults are recommended for the installation of glass front Use caution when handling glass Failure to do so could result in personal injury or property damage Note If optional logs are purchased arrange the logs on top of the crystal stones as desired ST4X8 SCREWS GLASS BRACKET C...

Page 13: ...ns Once the unit has been properly connected to a grounded electrical outlet turn on the power button located on the lower right side of the appliance A beep should be heard when the power is first applied See Figure 5 1 Power Button The Power button turns the power of the appliance on or off Flame Button By pressing the FLAME button the unit will cycle through four flame effects Heater Button The...

Page 14: ...ater button once heater turns on LOW Press Heater button twice heater turns on HIGH Press Heater button three times heater turns off LCD illuminates and displays heater status icon Fireplace emits single audible beep to confirm command to transition between HEATER states Fireplace displays one red LED for 10 seconds to confirm low heater command Fireplace displays two red LED for ten 10 seconds to...

Page 15: ...to set the desired room temperature The heater will only operate if the remote control tem perature set point is higher than the actual room tempera ture The heater will not operate if the actual temperature is greater than the remote control temperature set point To exit Thermostat mode toggle Temperature button until no temperature is displayed This function can also be used as a thermostat unde...

Page 16: ... not require further lubrication WARNING Risk of Fire To reduce risk of fire do not store or use gasoline or any other flammable vapors or liquids in the vicinity of the appliance WARNING Risk of Electrical Shock Any other servic ing needed must be performed by an authorized service representative Do not attempt to service the unit your self B Cleaning Cleaning Glass Dust particles can be removed ...

Page 17: ...MMENTS PART NUMBER 1 Crystal Media CRYSTAL ALLUS Y 2 Rotisserie 50 ROTISS ALLP50 Y 3 Remote Receiver RECEIV ALLUS E Y 4 Flame Motor MOTOR ALLP Y 5 Fan Heater HEATER ALLP Y 6 Glass Front 50 GLA ALLP50 Y 7 Trim 50 TRIM ALLP50 Y 8 Remote REMOT ELECT ALL Y 9 Main PCB PCB ALLP Y 10 Power Cord PLUGIN ALLP Y 11 LED Assembly 50 Ember and Flame Bed Included LED ALLP50 Y 12 Button Assembly TOUCH ALLP Y 13 S...

Page 18: ...CRIPTION COMMENTS PART NUMBER 1 Crystal Media CRYSTAL ALLUS Y 2 Rotisserie 60 ROTISS ALLP60 Y 3 Remote Receiver RECEIV ALLUS E Y 4 Flame Motor MOTOR ALLP Y 5 Fan Heater HEATER ALLP Y 6 Glass Front 60 GLA ALLP60 Y 7 Trim 60 TRIM ALLP60 Y 8 Remote REMOT ELECT ALL Y 9 Main PCB PCB ALLP Y 10 Power Cord PLUGIN ALLP Y 11 LED Assembly 60 Ember and Flame Bed Included LED ALLP60 Y 12 Button Assembly TOUCH ...

Page 19: ...CRIPTION COMMENTS PART NUMBER 1 Crystal Media CRYSTAL ALLUS Y 2 Rotisserie 72 ROTISS ALLP72 Y 3 Remote Receiver RECEIV ALLUS E Y 4 Flame Motor MOTOR ALLP Y 5 Fan Heater HEATER ALLP Y 6 Glass Front 72 GLA ALLP72 Y 7 Trim 72 TRIM ALLP72 Y 8 Remote REMOT ELECT ALL Y 9 Main PCB PCB ALLP Y 10 Power Cord PLUGIN ALLP Y 11 LED Assembly 72 Ember and Flame Bed Included LED ALLP72 Y 12 Button Assembly TOUCH ...

Page 20: ...___________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ Printed in China Copyright 2019 DO NOT D...

Reviews: