7
SimpliFire • SF-WMS38-BK • 2040-911 Rev. K • 4/20
D. Location
When choosing a location for your fireplace ensure that
the general rules are followed:
• For best results, install out of direct sunlight.
• Power supply service must be installed within
proximity of appliance prior to finishing to avoid
reconstruction.
• See Figure 3.1 for appliance dimensions and to
determine location of appliance installation.
E. Clearance to Combustibles
Minimum Clearance to Combustible Construction
Wall Mount (See Figure 3.2)
Sides.......................0 in.
Floor........................0 in.
Top..........................0 in.
Back........................0 in.
Front.....................36 in.
Stand
Sides.......................0 in.
Top..........................0 in.
Back........................0 in.
Front.....................36 in.
WARNING! Risk of Fire!
Keep electrical cords, drapery,
furnishings or other combustibles at least 3 ft. (0.9 m)
from the front of the appliance, and away from the sides
or rear.
Note:
One of the installation applications must be used.
F. Electrical Supply Circuit Requirements
Plan the location of the appliance so that it will have
adequate electric power. A 15 AMP, 120V/60hz. circuit
is required. Additional appliances on the same circuit as
this appliance may exceed the current rating of that cir-
cuit. A dedicated circuit is not required, but is preferred
to prevent circuit breaker trips or fuse failure.
Note:
Access to electrical outlet must be maintained.
Figure 3.2 Wall Mount Clearance to Combustibles
ELECTRICAL
OUTLET
LOCATION
Figure 3.3 Electrical Outlet Location
FLOOR
W
AL
L
CEILING
36 in. min