REV022618
SimpliPhi Power, Inc. | 420 Bryant Circle | Ojai, CA 93023, USA | (805) 640-6700 | info@simpliphipower.com |
SimpliPhiPower.com
| 16 |
Potential Health Effects:
Inhalation:
Inhalation of material from a sealed PHI 2.7 Battery is not an expected route of exposure.
Vapors or mists from a ruptured PHI 2.7 Battery may cause respiratory irritation.
Ingestion:
Swallowing of material from a sealed PHI 2.7 Battery is not an expected route of exposure.
Swallowing mists from a ruptured PHI 2.7 Battery may cause respiratory irritation, chemical burns of the
mouth and gastrointestinal tract irritation.
Skin:
Contact between the PHI 2.7 Battery and skin will not cause any harm. Skin contact with positive
and negative terminals of high voltages may cause burns to the skin. Skin contact with a ruptured PHI 2.7
Battery can cause skin irritation.
Eye:
Contact between the PHI 2.7 Battery and eye will not cause any harm. Eye contact with the contents
of a ruptured PHI 2.7 Battery can cause severe irritation to the eye. Medical Conditions Aggravated by
Exposure: Not Available
A.4 – First Aid Measures
Skin Contact:
Wash affected area with lukewarm water for at least 30 minutes. If irritation or pain
persists, seek medical attention.
Eye Contact:
Wash affected eye with lukewarm water for at least 30 minutes. Rinse with saline solution if
possible. Seek medical attention.
Inhalation:
Move victim to fresh air and remove source of contamination from area. Seek medical
attention.
Caution:
In all cases if irritation persists, seek medical assistance at once.
A.5 – Firefighting Measures
Extinguishing Media:
Water, carbon dioxide, dry chemical powder and foam are most effective means to
extinguish a Lithium Ferrous Phosphate (LFP) battery fire.
Fire Fighting Procedure
: Put on fully protective gear, including self-contained breathing apparatus,
goggles, fireproof jacket and gloves.
Unusual Fire and Explosion Hazards:
Exposing PHI 2.7 Battery pack or cell to excessive heat, fire or
over voltage condition may cause a leak, fire, hazardous vapors and hazardous decomposition products.
Damaged or opened cells can result in rapid heating and the release of flammable vapors.