SimpliPhi Power, Inc. | 420 Bryant Circle | Ojai, CA 93023, USA | +1 (805) 640-6700 | info@simpliphipower.com |
SimpliPhiPower.com
| 15 |
Connecting Cable Leads to the PHI2.6™ Smart-Tech
Batteries:
NOTICE: SPARK MAY BE PRESENT WHEN CONNECTING WIRES TO PHI2.6™ TERMINALS
A brief small spark is often present when connecting the second of two leads to a battery. Example: If the
Positive has been connected, a small spark will likely be present when connecting the Negative lead.
This
is a normal occurrence. Complete all connections in a clean, ventilated, well lit area. To avoid any spark or
electrical event when connecting the terminal leads on the PHI2.6™ Smart-Tech Battery, turn the 80 Amp
breaker “ON/OFF” switch to “OFF” position.
Power Cabling for the PHI2.6™ Smart-Tech Battery is not included. Your qualified installer or application
specifications will determine the wire gauge for your system.
Considerations for Power Cable Terminations
- PHI2.6™ Smart-Tech Battery Mounting Stud Size: 3/8’’
- Power Cable Wire Gauge: Generally anywhere from 6 AWG to 2/0 AWG or larger.
High amperage rated ring terminals can be found for these and other common dimensions. Your installer
can source these or we can provide them based on the specifications you provide.
Protection from the Environment
Anticorrosive compounds or epoxies are occasionally used in harsh or marine climate installations. Please
contact your Electrician or Qualified Installer to determine if this is advisable, and if so, what solution best
suits your application.
Final Connection of the Installation
Final installation and operation guidelines will be dictated by your Electrician and Installer based on the
overall properties of and procedures for the equipment in your installation and any code requirements
that apply to your region. SimpliPhi Power, Inc. technicians and sales staff are available to provide any
additional information on the PHI2.6™ Smart-Tech Battery as needed. Please contact SimpliPhi Power for
any technical support at your convenience. SimpliPhi Power, Inc. is committed to providing safe, reliable
energy storage and management that is maintenance free, non-toxic and long-lasting. This commitment
extends to our customers, valued installers, partners, and to the community at large. Please be aware
of the potential electrical hazards before interacting with any and all electrical or mechanical devices.
Please take all necessary precautions in your projects and installations. Please refer to page 4 for safety
guidelines.
PHI Smart-Tech Batteries feature a Low Battery Voltage Cut Off (LBCO). This is a self protection mechanism
that prevents over discharge. The LBCO will cause the battery to turn off once batteries approach Zero
Capacity or 100+ percent depth of discharge.