background image

Getting Started DKIT-05 

Landscape-Outdoor Lighting Kit

 

Simply Automated, Incorporated 

6108 Avenida Encinas, Suite B, Carlsbad, CA  92011 USA 

Technical Support:  

www.simply-automated.com

 or 

800-630-9234

 

  452-0001-0005WEB Rev. B   Revised: September 22, 2011

 

 

Simply Automated Pre-Configured SimplySmart

TM

 Series 

Utilizes SimplySmart

TM 

technology to make installation a breeze.  

No computer programming required!  

Simple-n-easy, ready to use lighting control.

 

 
 

IMPORTANT SAFETY INSTRUCTIONS 

When using electrical products, basic safety precautions should always be followed, including the following: 

1. 

READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 

2. 

Keep away from water.  If product comes into contact with water or other liquid, disconnect immediately. 

3. 

Never use products that have been dropped or damaged. 

4. 

Do not use this product outdoors, unless protected by a weatherproof enclosure. 

5. 

Do not use this product for other than its intended use. 

6. 

Do not connect multiple loads that, when combined, exceed the maximum load rating of the product. 

7. 

To avoid risk of fire, burns, personal injury and electric shock, install this product out of reach of small children.  

8. 

Do not install in areas that can exceed 120°F (e.g., in an attic). 

9. 

Do not cover the product with any material when in use. 

10.  This product uses polarized plugs and sockets (one blade is wider than the other) to reduce the risk of electric shock.  These plugs and 

sockets fit only one way.  If they do not fit, consult a technician.  Do not use with an extension cord unless plugs can be fully inserted.  Do 
not alter plugs. 

11.

 

SAVE THESE INSTRUCTIONS.

 

 
 

 
DKIT-05 Outdoor-Landscape Relay Starter Kit 

Includes 2 Appliance (relay) Modules and 1 Scheduler-Timer Controller

 

 
  

Getting Started 

 

Section 1:  Very Important Pre-Installation Notes 

 

 

Your home should be no more than 2500 square feet and have only one breaker panel.  A phase coupler is 
required in some home installations; especially homes > 2500 square feet or homes with more than 1 
breaker panel.  See Section 6 for more information.  

 

Not intended for use in multi-dwelling (condo, apartment) buildings with 3-phase power.

 

 

Do not reset to factory default configuration, pre-configured settings will be lost.  

 

UPStart

 software and a 

computer interface module

 or Scheduler-Timer can be used with a PC for 

customizing pre-configured units and checking performance. 

 

 

 

Section 2:  Installation of Appliance (relay) Modules and Scheduler-Timer Controller

 

  

Find a convenient location you would like to use for the Scheduler-Timer (e.g. outlet in garage, office, kitchen or 
closet) and plug in the Scheduler-Timer controller.  Locate 2 electrical loads you would like to turn ON/OFF with 
the relay modules, such as outdoor low-voltage lighting transformers, appliances, pump/motors or lights.  Plug a 
relay module into a wall outlet (or the outlet used for a timer in the outdoor lighting transformer).  Next, the power 
cord of the electrical load (transformer) to be controlled plugs into the socket on the bottom of the appliance 
module.  Note, the convenience outlet on the front of the appliance module is always ON and is not ON/OFF 
controlled.  If there is an ON/OFF switch on the plugged in electrical load, then turn the load switch ON.  Repeat 
this process for second relay module.  You're done with the installation process!  If necessary, please refer to the 
User Guide enclosed in the Appliance Modules product box or see 

http://www.simply-

automated.com/documents/452-0013-0101_RevF_UMA_UserGuide_090512.pdf

 

Summary of Contents for DKIT-05

Page 1: ...Lighting Relay Starter Kit Model DKIT 05 Simply Automated Pre Configured SimplySmartTM Series Utilizes SimplySmartTM technology to make installation a breeze No computer programming required Simple n...

Page 2: ...t Includes 2 Appliance relay Modules and 1 Scheduler Timer Controller Getting Started Section 1 Very Important Pre Installation Notes Your home should be no more than 2500 square feet and have only on...

Page 3: ...trolled by the scheduler or other pre configured scene controllers Go to the location of the second relay module labeled 19 and repeat the steps above to ensure the relay module and the connection to...

Page 4: ...Right or Left button to the Day of the Week field and use the Up or Down buttons to set the day of the week Find an accurate clock e g cell phone time referenced on a TV station or go to www time gov...

Page 5: ...ter button and the scheduler will calculate sunrise dawn and sunset dusk for your location Press the Enter button again to save these settings and return to the main Menu You are done setting the Loca...

Page 6: ...be set to turn ON at dusk and OFF at 11PM when the scheduler is in the regular runtime RUN schedule mode If you would like to set ON OFF times other than Dusk 11PM feel free to do so Set Event 01 Wit...

Page 7: ...he cursor on 01 press the Enter button to activate turn on the event Press the Enter button again to deactivate turn off the event You should see the relay module 18 and the connected load transformer...

Page 8: ...ge any day to a 02 SMTWTFS R 12 00A 12 00A LA 02 019 SMTWTFS R 12 00A 12 00A LA Press the Right button to move the cursor to the event mode field Using the Up or Down buttons set the event mo normal r...

Page 9: ...b Section 4 e Setting Event 03 for a Group SCENE of Modules The relay modules 018 and 019 as labeled on the back of the units are pre configured to operate with the optional 4 and 8 button scene contr...

Page 10: ...when pressing the Enter bu ection 6 S Section 4 g Other Functions of the Scheduler Timer To learn more about the Scheduler Timer and functions such as deleting an event or setting randomness please r...

Page 11: ...0 square feet and have only one breaker panel A phase coupler is required in some home installations especially homes 2500 square feet or homes with more than 1 breaker panel If you have tested the sc...

Page 12: ...p to 250 devices using your PC and UPStart software Devices include single rocker dimmers deluxe dimmers with different faceplates up to 8 buttons lamp or appliance modules tabletop pedestal with 4 or...

Reviews: