background image

STEP 4

Untwist and straighten the wire conductors. We recommend using the Simply45 

Adjustable LAN Cable Stripper (

S45-S01BL/YL

) that has a wire straightener comb on 

the top. Next, align the wires in the correct alignment pattern (Type A or B).  

The B pattern is the most used today.

T568A

GR BL

T568B

WO WG WBL WBR

WG

TOP ROW

BOTTOM ROW

WO WBL WBR

STEP 5

Using the 

S45-801

 Flush Cutter, trim 

the solid wires back about 3/4” (2cm).

STEP 6

Following the pattern above, insert 

the 4 striped wires first. Make sure the 

wires are fully laid into the load bar.

Then insert the 4 solid wires

Summary of Contents for S45-1155

Page 1: ...he Simply45 S45 1155 Standard Series Shielded External Ground RJ45 Modular Plugs for 10G Shielded and other large diameter shielded LAN cables Our S45 1155 plugs include the uniquely designed and patent pending Bar45 Simply45 Standard Series Shielded RJ45 Modular Plugs patent pending ...

Page 2: ... as close to the jacket as possible STEP 2 Slide the S45 1155 metal shell onto the cable jacket with the front of the shell facing the termination end Slide it back out of the way for the moment STEP 1 Using the Simply45 Adjustable LAN Cable Stripper S45 S01BL YL or wire stripper on the Simply45 Heavy Duty RJ45 Crimp Tool S45 C100 S45 C101 score the cable jacket about 2 5cm from the cable end Be s...

Page 3: ...he wires in the correct alignment pattern Type A or B The B pattern is the most used today T568A GR BL T568B WO WG WBL WBR WG TOP ROW BOTTOM ROW WO WBL WBR STEP 5 Using the S45 801 Flush Cutter trim the solid wires back about 3 4 2cm STEP 6 Following the pattern above insert the 4 striped wires first Make sure the wires are fully laid into the load bar Then insert the 4 solid wires ...

Page 4: ...lush Cutter trim the wire ends straight leaving about 0 2 5mm protruding past the front of the Bar45 load bar STEP 8 Insert the cable with the Bar45 into the plug The S45 1155 plug is designed to accommodate insertion of large diameter cables up to 8 0mm 0 315 Work the cable jacket into the plug until fully inserted Looking from underneath the plug the cable jacket should meet or come close to the...

Page 5: ...e should remain straight back against the cable jacket and come out of the back of the shell and extend pass the external ground arm STEP 9 Insert the loaded plug into the Simply45 Heavy Duty RJ45 Crimp Tool S45 C100 S45 C101 Make sure to completely insert the plug into the crimper socket STEP 10 Compress the crimper handles all the way down with one swift and firm motion until the handles release...

Page 6: ...d the cable jacket STEP 14 Using the external ground arm crimp feature on the Simply45 Shielded External Ground Crimper S45 C101 crimp the external ground wings until securely folded around the cable jacket You can also use pliers S45 802 to accomplish this task STEP 15 Inspect the finished product Simply45 and Bar45 are trademarks of Simply45 LLC All rights reserved You can view these instruction...

Reviews: