STEP 7
Slide the Bar45 load bar as far back to the cable jacket as you can. Bar45 is designed
to slide back almost touching the cable jacket. [NOTE: This is important for reducing
the length of untwisted wire inside the RJ45 plug and improving termination
performance]. Next, using the
S45-801
Flush Cutter, trim the wire ends straight
leaving about 0.2” (5mm) protruding past the front of the Bar45 load bar.
STEP 8
Insert the cable with the Bar45 into the plug. The
S45-1155
plug is designed to accommodate
insertion of large diameter cables up to 8.0mm (0.315”). Work the cable jacket into the plug until
fully inserted. Looking from underneath the plug, the cable jacket should meet or come close to
the horizontal line (see above). Make sure the drain wire remains straight down the cable jacket.