Construction
The MegaDumper consists of a steel frame with two vertical masts and stabilizing legs, a bin
cradle, two hydraulic rams, lifting chains, guarding, powerpack cover, control panel, castor
wheels, power lead or batteries, hydraulic powerpack and electronic control systems.
1.3
Mechanism
When the RAISE button is pressed, two hydraulic rams are extended, which pull on an
arrangement of chains, causing the bin cradle to travel vertically in the masts. The cradle is
inverted at the appropriate height by an arrangement of arms, rollers, and curved tracks.
The rams are supplied by a hydraulic pump, which may be driven by a 3-phase, 1-phase,
battery, or compressed-air motor. Electrical, hydraulic, and mechanical control systems allow
the operator to lift and lower the bin in a controlled manner.
1.4
Safe Lifting Capacity
The Safe Lifting Capacity of the standard MegaDumper is
600kg (550lb)
.
Some machines may be specified with different capacities. Refer to the rating plate to verify
the
f c ’
Safe Lifting Capacity on any given machine.
Safe Lifting Capacity is a gross figure, referring to the weight of the bin, its contents, and
any other external objects which have been placed on the cradle.
Never attempt to lift bins heavier than the
ch ’
Safe Lifting Capacity.
1.5
Duty cycle
The duty cycle of the MegaDumper depends on the type of power supply and powerpack
that is fitted to the machine, as well as various environmental factors and the manner in
which the machine is used. The figures given below are estimates only.
Power supply
Duty Cycle (tipping ~300kg bins at 1800mm)
Net throughput
Number of bins
Units
24V/40Ah Gel Battery*
15,000kg
300 bins
Per charge
24V/40Ah Gel Battery with
continuous charge
3,000kg
10 bins
Per hour
24V/40Ah Gel Battery with solar
panel kit**
6,000kg
20 bins
Per day
Mains, 3-Phase ~415VAC
12,000kg
40 bins
Per hour
Mains, 1-Phase ~230VAC***
9,000kg
30 bins
Per hour
*4x 12V/20Ah batteries in series; default from 2015 **Subject to weather, latitude, and panel orientation; see