1.6
Service life
The nominal service life of the MegaDumper is as follows:
Average Gross Bin Weight
Intended operational life
< 200kg
100,000 cycles
200kg
–
300kg
75,000 cycles
300kg
–
500kg
50,000 cycles
500kg
–
600kg
25,000 cycles
> 600kg
10,000 cycles
1.7
Noise emissions
The noise emissions of the MegaDumper do not usually
xc ~ B(A) h ’
ear. Hearing protection is recommended if operating the machine for extended periods.
ISO standards specify that machinery noise emissions be measured in A-weighted
decibels, or dB(A). This is a unit of volume adjusted to reflect the sensitivity of human
hearing. Measurements for a dB(A) assessment are taken at a point 1.6 metres above the
h ’ w k
1.8
Environmental restrictions
The MegaDumper may be used indoors or outdoors. However the following restrictions apply:
1.
Minimum floor area 4 square metres, with a clear passage to exits;
2.
Height above sea level not more than 1000m;
3.
Ambient temperature not higher than +40
℃
and not lower than -10
℃
;
4.
At ambient temperatures above 35
℃
, the relative humidity should not exceed 50%; at
lower temperatures, higher relative humidity is permitted;
Never operate the MegaDumper in explosive, corrosive, acidic or alkaline environments.
1.9
Ingress protection
Item
IP Rating
Push buttons, switches, and lamps
IP66
Door interlock
IP66
Coded magnetic switch
IP66
Motor
IP54 (additional protection is provided by covers)
Overall