Water testing (Optional)
To monitor the performance of your SimPure
®
T1 Water Purification
system, you will need a water meter that can test the impurities in water.
SimPure
®
has a simple to use handheld TDS meter designed for this
purpose.
It is recommended you follow the Monthly Maintenance procedure before
taking a water sample:
•
STEP 1 –
OPEN the gooseneck faucet tap and run about one quart (1
liter) to drain before sampling the water
•
STEP 2
– Rinse a clean cup or small container with the purified water
and disregard, refill container.
•
STEP 3
– Place the SimPure
®
TDS Meter in the solutions and follow the
instruction to take a TDS reading
•
STEP 4
– Once you have a purified water reading, you should then test
the feedwater. Run some water from your standard cold sink water
tap into a clean cup or small container and test the TDS.
Now that you have a water quality reading from the feedwater and the
purified water, you can compare and see how well your water purification
system is operating.
As a general guide, the purified water TDS level should be >90% lower
than the incoming feedwater indicating the system is working well;
however, this does depend on feedwater quality, which can be
substantially different from one region to another.
•
Replacing Consumables
It is important to maintain the filters and RO membrane to ensure the
outlet water quality is a consistently high standard.
The life expectance of filters and replacement schedule is dependent on
source water quality and water consumption.
Under normal situations, we recommend users replace filters as per the
table below:
Replacement Consumables Cartridges
Description
Replacement
Schedule
(months)
Part Number:
PP Filter
3 – 6
RSWF003Z
(Kit of 4 Cartridges)
GAC (UDF Filter)
3 – 6
CTO Filter
3 – 6
T33 Filter
3 – 6
Reverse Osmosis (RO)
for 75 GPD model*
6 - 12
RSRO004
Reverse Osmosis (RO)
for 100 GPD model*
6 - 12
RSRO005
*Note: Depending on your system type order either the 75 or 100 GPD.
25
26
SimPure
®
TDS Meter
Part Number:
RSTDS001_S8