Flushing Indicator Light & Button
Power on –
The System will automatically
flush for the first 30 seconds. If the Feed
Water Tank exceeds the MAX level – The
System will flush for only 18 seconds.
Manual Flush
- Push the button, and the
System will flush for 60 seconds and stop. To
cancel the manual flush, push the button a
second time. While flushing, the indicator
light will be on.
Emptying function -
Push and hold the
Flushing button for 5-seconds; purified water
will start to flow from the outlet until the
internal Tank empties. You will hear 1-beep;
the Flushing button will be lit blue. To
manually stop dispensing water, push any
other button, the blue light goes off.
UV Indicator Light
Steady –
While purifying water, the UV light
will operate, staying on a further 1-hour
after the pure water tank is full.
Startup –
When the System is reconnected
to the power outlet, the UV will function for
the first 3-hours and then shut off
automatically.
Standby
- The UV light will operate for 15
minutes every 20 minutes to help maintain
microbial control of the purified water.
Change Water Indicator Light
Flashing
–Feed tank water lower than the
Min. Level. You will hear 10-beeps, and the
System starts up, releasing pressure for 10
seconds. Once complete, remove the Feed
Tank, empty ALL the remaining concentrate
water, and refill with fresh potable (tap)
water (do not reuse the remaining water as it
will be high in salts). Refit the Feed Water
Tank to the System.
Steady
– Feed Tank has been removed from
the base. Light will go out when the Tank is
returned into the System.
IMPORTANT:
If you do not remove and empty the Feed Water Tank and
instead add water directly to the Tank, the Change Water indicator light cannot
be cleared. Lift the Feed Water Tank out of the System, empty the concentrate
and refill with fresh potable (tap) water, then replace the Tank into the System
to clear the Change Water indicator light.
Water Shortage Indicator Light
Steady –
Internal pure water reservoir low
Flashing
- The System automatically starts
filtering water refilling the internal reservoir.
NO water can be dispensed while the light is
flashing.
Off -
When filtered water is available in the
internal reservoir, the Water Shortage
indicator light goes out, and you can dispense
water again.
13