Chapter 9-2
CP33 Setup menu
+/-
Toggle between available values
Serial number: 0x00ffffff
Interface software version: 0x00000025
GPS receiver type: N11999
PAGE rotation interval: 05 sec.
Display text in: English GB
Example of
the Speed
alarm, units
& language
display,
page 2.
PAGE
More (2/2) Scroll
MENU
Exit Accept
ENT
ENT
Confirm changes, or...
MENU
exit function without making any changes
Setup for speed:
LOG speed sensor
- set to ON, the dual speed display will show
water speed from external log sensor (via ECHO port).
- set to OFF and NMEA sentence VHW set to ON, the readout will
show water speed from external water speed instrument (via NMEA
port).
LOG speed calibration
- calibrate log speed readout by increasing/
decreasing the number of pulses per nautical mile - see also Appen-
dix A.
Speed alarm
- can be set to maximum and/or minimum cruising
speed. This may be handy for trawl fishing, entering harbors with
speed limits, etc.
Speed stability and time of response can be adjusted in position
setup display, press [MENU], [2], [1], [ENT], and use the cursor
key to go to “Speed filter level” to adjust the setting, confirm with
[ENT].
Press [CLR] to reset an alarm - this applies to all activated alarms in
the system.
Summary of Contents for CP33
Page 14: ...Chapter 1 8 CP33 Introduction and safety summary ...
Page 44: ...Chapter 3 22 CP33 Chart menu and INFO windows ...
Page 60: ...Chapter 4 16 CP33 Position menu ...
Page 76: ...Chapter 5 16 CP33 Waypoint route menu ...
Page 114: ...Chapter 9 12 CP33 Setup menu Page 1 of 2 Page 2 of 2 ...
Page 118: ...Chapter 10 2 CP33 Installation and service Important settings continued ...
Page 130: ...Chapter 10 14 CP33 Installation and service ...
Page 134: ...Appendix A 4 CP33 Glossary of terms ...
Page 144: ...Appendix C 8 CP33 C MAP attributes ...
Page 149: ...CP33 Chartplotter Index ...