EQ-55 Operators Manual
950-7001001/Iss 1.2
Introduction and System Familiarization
Page 7.5
Kongsberg Simrad Mesotech Ltd.
Port Coquitlam, BC - Canada
7.3
SERVICING THE EQ 55 AIR FILTER
The EQ 55 air filter should be cleaned once each month under normal operating
conditions. If operating in a dusty or dirty environment, cleaning every 24 hours
may be necessary to avoid restricting the passage of cooling air through the EQ 55.
The EQ 55 fan cooling system is designed to draw air in through the filter, pass it
throughout the EQ 55, and exhaust through the vent slots in the bottom of the
case.
To clean the EQ 55 air filter, remove power from the unit. With the rear of the EQ
55 facing you, remove the fan shroud. You can now see the filter and the filter
frame which holds it in place. The filter can be removed by lifting each side away
from the fan housing.
Wash the filter thoroughly in water and wring dry. Allow to air dry
thoroughly
.
Reinstall by reversing the removal process. Ensure that the fan shroud is snapped
securely in place.
7.4
EQ 55 DISASSEMBLY INSTRUCTIONS
The EQ 55 main electronics can be remove without removing the entire unit from
its location.
7.4.1
Removing the EQ 55 Electronics Drawer
Disconnect and mark all cables from the EQ 55. With the front facing you, remove
the 4 Hex bolts of the front panel. Slide the drawer out from the main housing of
the EQ-55 and disconnect the video cable and the plug that is attached to the
drawer.
7.4.2
Removing the Lid From the Drawer
To remove the lid of the drawer remove the 11 Phillips screws located around the
outside edge and the 5 Philips screws located on the left side on top of the lid.
7.4.3
Removing the Transceiver Printed Circuit Board Assembly.
The Transceiver printed circuit board assembly is the top board in the EQ 55
drawer.