EQ-55 Operators Manual
950-7001001/Iss 1.2
Operation of the EQ-55
Page 2.25
Kongsberg Simrad Mesotech Ltd.
Port Coquitlam, BC - Canada
2.5.1
Gain - LF and HF Gain
The Low Frequency and High Frequency channels
each have their own receiver, and so each has its
own Gain adjustment.
The Gain is adjustable in steps from 0 (minimum) to
15 (maximum). The "correct" Gain setting for your
installation depends on many variables affecting the
strength of the return echoes, such as Transmit
Power settings, transducer election and placement,
water conditions and target strength.
MAIN MENU
LF SETTING
HF SETTING
DISPLAY MODE
EXPANSION
SET MARKER
GAIN
TRANSMIT POWER
CONFIGURATION
↓↓↓↓
GAIN
LF GAIN
HF GAIN
LF GAIN
15
Ù
15
Ú
0
STATUS