Description
This page allows you to obtain more accurate temperature and depth readings by providing
offset values. You do not need to adjust these settings if your readings are correct. For
the depth reading, anywhere above the waterline should report zero. If not, then enter an
offset to calibrate the sensor. For example, if the depth reading is reporting as 2m above
the waterline, then enter an offset of -2m.
If you have applied an offset, a (B) will appear before the sensor reading in the trawl sensor
status pane. (B) will also appear in the readings shown in all the sonar views and in the
Depth and Temperature graphs.
Details
Depth Offset
When the deployment depth sensor reading is not accurate, use this offset to
compensate the depth reading.
Temperature Offset
When the deployment temperature sensor reading is not accurate, use this offset to
compensate the temperature reading.
Related topics
Improving the Trawl Unit sensor readings, page 63
Sensor Export dialog box
The
Sensor Export
dialog box allows you to control the properties of each available
communication channel providing output from the FM90 Processor Unit, and to select
which data to export.
How to open
Click the
Sensor Export
button. This button is located on the top bar.