40
922-00027001/2.2
Powering the FM90 on and off
Topics
Powering up the FM90 for normal use, page 40
Powering off the FM90, page 41
Powering up the FM90 for normal use
To power up the FM90, use the ON/OFF power switch on the front panel of the Power/VDSL
Unit.
Context
The ON/OFF switch on the rear panel powers up the Power/VDSL Unit. The ON/OFF
switch on the front panel powers up the Sonar Head.
Note
After powering up the FM90, there will be a brief delay before the Processor Unit discovers
the Sonar Head. The length of this delay depends on external factors, such as the length of
your third-wire trawl cable. Wait for the VDSL/STATUS light on the Power/VDSL Unit to
turn solid green before attempting to connect to the Sonar Head.
Procedure
1
Turn the Sonar Head on using the ON/OFF power switch (A) on the Power/VDSL
Unit front panel.
2
Switch the voltage selector (B) to 200 VDC.
3
Confirm that the voltage meter (C) shows 200 VDC and the current meter (D) shows
the current is less than 0.5 A.
Simrad FM90 Reference Manual