Description
If you have external sensors that provide speed, heading, or latitude/longitude coordinates,
then this dialog box allows you to set them up. Readings from these sensors will appear in
the
Information Widget
located in the sonar view.
Details
Add Device
Click this button to add a sensor for data import.
Remove Device
Click this button to remove the selected sensor from the
Sensor Devices
list.
Test Device
Click this button to start a sensor test. The sensor data will be displayed in the
Port
Monitor
box.
Device Properties
•
Name
Enter any name into this field to label the device.
•
Protocol
This drop-down lists all supported datagram formats.
•
Port Location
The location of the port receiving external sensor data – can be either a COM port
or UDP Ethernet port.
•
Port#
This drop-down lists the available port numbers. Select the port where the device
is connected.
•
Baud Rate
Specify the baud rate (“speed”) for the serial communication. The standard baud
rate defined for NMEA communication is
4800
.
•
Data Bits
Select the number of data bits for the serial communication.
Note
The standard number of data bits defined for NMEA serial line communication is
8 (eight).