Simrad GC80/85 Double System Controller
80
988-12721-001
Relevant information:
If an alert or symptom is not fixed, contact SIMRAD service center.
TS-19 - Switch failure of the heading sensor
Procedure and treatment:
1
Check the condition of the service switches SW101 and SW102. Then
check the fuses XF101 and XF102 in the system.
Relevant information:
If an alert or symptom is not fixed, contact SIMRAD service center.
TS-20 - CPU restart detection
Procedure and treatment:
1
Check the heading information of the gyrocompass and the external
heading sensor which is displayed in the system coincides with the
heading information of each heading sensor.
2
Check that the heading information of the equipment connected
with the system coincides with the heading information of the
heading sensor selected by the system.
Relevant information:
The alert is cleared by restarting the system.
Perform it when the vessel is at anchor.
TS-21 - Gyrocompass integrity failed
Procedure and treatment:
1
Check the working condition of the gyrocompasses.
2
Check the setting parameter of the gyrocompasses (latitude, vessel
speed).
Relevant information:
If an alert or symptom is not fixed, contact SIMRAD service center.
TS-22 - Gyrocompass integrity doubtful 1
Procedure and treatment:
1
Check the working condition of the unselected gyrocompass.
2
Check that the unselected gyrocompass has been started more than
about 3 hours ago (Not under standby mode).
Relevant information:
If an alert or symptom is not fixed, contact SIMRAD service center.
TS-23 - Gyrocompass integrity doubtful 2
Procedure and treatment:
1
Check the alarm condition of selected gyrocompass.
2
Check if the GPS or the LOG communication error is ON, recover the
system.
Summary of Contents for GC80 EXPANDED
Page 1: ...ENGLISH GC80 85 Double System Controller User Manual www navico commercial com...
Page 2: ......
Page 3: ...Simrad GC80 85 Double System Controller 988 12721 001 3 Document history Rev 001 First review...
Page 31: ...Simrad GC80 85 Double System Controller 988 12721 001 31...
Page 42: ...Simrad GC80 85 Double System Controller 42 988 12721 001...
Page 43: ...Simrad GC80 85 Double System Controller 988 12721 001 43...
Page 44: ...Simrad GC80 85 Double System Controller 44 988 12721 001...
Page 45: ...Simrad GC80 85 Double System Controller 988 12721 001 45...
Page 82: ......
Page 83: ...988 12721 001...