16 |
Installation |
Loop M User Manual
F
M8 ring terminal (not included in the box)
Output ports
Each Egon+ board has 8 controllable relays protected by 8 individually monitored fuses. Each
relay can be manually bypassed by an external signal. In addition each Egon+ board has 8
fuse protected outputs that can be monitored.
1D
1C
1B
1A
1E
1G
1H
2C
2B
2A
2E
2G
2H
3A
3G
3H
4D
4C
4B
4A
4E
4F
4G
4H
A
B
C
D
A
Output port 1 (black)
B
Output port 2 (gray)
C
Output port 3 (blue)
D
Output port 4 (green)
Output port 1 (black)
Output port 2 (gray)
1A - bypass for relay R3
2A - output fuse F12
1B - bypass for relay R2
2B - output fuse F11
1C - bypass for relay R1
2C - output fuse F10
1D - bypass for relay R5
-
1E - bypass for relay R7
2E - output relay R8 (fuse F14)
-
-
1G - bypass for relay R6
2G - output fuse F15
1H - bypass for relay R8
2H - output fuse F16
Output port 3 (blue)
Output port 4 (green)
3A - bypass for relay R4
4A - output relay R1 (fuse F1)
-
4B - output fuse F8
-
4C - output fuse F6
-
4D - output relay R4 (fuse F7)
-
4E - output relay R3 (fuse F5)
-
4F - output relay R2 (fuse F3)
3G - Output relay R6 (fuse F9)
4G - output fuse F4
3H - Output relay R5 (fuse F2)
4H - output relay R7 (fuse F13)
Bypassing a relay
The bypass is an override and it cannot be used as a parallel control. By connecting the
bypass pin of a relay to DC negative the relay is closed and the output activated. If the output
is already activated by the software, connecting the bypass pin to DC negative has no effect.
It is not possible to turn off an output with an active override from the software.
The main important appliances (bilge pumps, navigation lights, blower, horn etc) must be
equipped with a bypass for the safety of the boat.