152
419050/B
Important
The transducer is covered with a thick red protective coating made of a special
plastic type. The red protective coating is an vital part of the transducer. It is very
important that neither this coating nor the internal parts of the transducer are
damaged during the handling, installation or cleaning.
8
Align the mounting holes.
9
Mount and tighten the flange nuts.
Use the following torque: 60 Nm.
Designing and mounting mechanical support
brackets to secure the hull unit
Due to its height and weight, the hull unit gantry must be secured to the bulkhead by
means of mechanical support brackets. The dimensions and strength of the support
brackets must be adequate to prevent vortex induced vibration. This a requirement to
ensure the safety of the SC90 and the vessel.
Prerequisites
The shipyard must provide all necessary tools and manpower.
Context
A
Removable support brackets
B
Bulkhead
C
Hull Unit
The forces to which the hull unit is
exposed depends on the physical size
of the installation, where it is located,
and the vessel's behaviour in rough
sea. It is very important that the
hull unit is sufficiently supported, as
the forces it is exposed to may affect
both the physical installation and the
vessel's safety.
The mechanical support brackets
must be designed and manufactured by the installation shipyard to fit the complete
installation in the sonar room. All calculations made to support the design must meet
the applicable safety requirements, and apply to the physical properties of the hull and
the installation.
Simrad SC90 Installation Manual
Summary of Contents for SC90
Page 2: ......
Page 16: ...14 419050 B Simrad SC90 ...
Page 219: ...419050 B 217 Øverland UPC 3005 Dimensions Cable layout and interconnections ...
Page 223: ...419050 B 221 Øverland UPC 5000P Dimensions Cable layout and interconnections ...
Page 438: ...436 419050 B 427177 Transducer dock dimensions page 494 Simrad SC90 Installation Manual ...
Page 441: ...419050 B 439 Drawing file ...
Page 442: ...440 419050 B Simrad SC90 Installation Manual ...
Page 445: ...419050 B 443 Drawing file ...
Page 452: ...450 419050 B Simrad SC90 Installation Manual ...
Page 455: ...419050 B 453 Drawing file ...
Page 458: ...456 419050 B Simrad SC90 Installation Manual ...
Page 463: ...419050 B 461 Drawing file ...
Page 468: ...466 419050 B Simrad SC90 Installation Manual ...
Page 469: ...419050 B 467 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 471: ...419050 B 469 Drawing file ...
Page 473: ...419050 B 471 214043 Gate valve installation DN350 Drawing file ...
Page 475: ...419050 B 473 422915 Gate valve installation DN350 Drawing file ...
Page 477: ...419050 B 475 083045 Gate valve installation DN500 Drawing file ...
Page 479: ...419050 B 477 33414 Gate valve dimensions DN350 Drawing file ...
Page 480: ...478 419050 B Simrad SC90 Installation Manual ...
Page 481: ...419050 B 479 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 482: ...480 419050 B 33473 Gate valve dimensions DN350 Simrad SC90 Installation Manual ...
Page 483: ...419050 B 481 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 484: ...482 419050 B 33498 Gate valve dimensions DN500 Simrad SC90 Installation Manual ...
Page 485: ...419050 B 483 Drawing file ...
Page 487: ...419050 B 485 37357 Gate valve dimensions DN500 Drawing file ...
Page 488: ...486 419050 B Simrad SC90 Installation Manual ...
Page 489: ...419050 B 487 Related topics Installing the optional gate valve DN500 page 103 Drawing file ...
Page 491: ...419050 B 489 Drawing file ...
Page 494: ...492 419050 B Simrad SC90 Installation Manual ...
Page 495: ...419050 B 493 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 497: ...419050 B 495 Drawing file ...
Page 542: ... 2018Kongsberg Maritime ISBN xxx ...
Page 543: ......
Page 544: ...Simrad SC90 Fish finding sonar Installation Manual ...