Testing the SC90 operational functionality
Topics
Checking the transducer lower and hoist functionality, page 341
Testing the Operating Panel to verify basic functionality, page 345
Testing the user interface to verify basic functionality, page 349
Verifying SC90 operation by means of the BITE functionality, page 351
Measuring the output voltages from the Power Supply Unit, page 357
Making a noise/speed curve to determine vessel noise, page 358
Checking the transducer lower and hoist functionality
The hull unit provided with the SC90 is designed to lower the transducer down below the
ship’s hull when the SC90 shall be used. This is a key functionality of the SC90. It is very
important that the hoist/lower function is tested before the SC90 is put to operational use.
In order to test the lower and hoist functionality of the hull unit, two tasks must be done
simultaneously. Two persons are required.
• One person must stay on the bridge in order to operate the SC90.
• One person must stay in the sonar room to verify that the Transceiver Unit starts, and
that the hull unit works properly.
Certain steps in the two procedures are location specific.
• The steps marked [
Sonar room
] are done in the sonar room.
• The steps marked [
Bridge
] are done on the bridge.
Note
Proper oral communication must exist between the bridge and the sonar room. In the
event of problems or malfunctions:
1
Locate the
Motor Protecting Switch
(S301).
2
Set the switch to position OFF.
Topics
Checking the transducer lower and hoist functionality - Bridge steps, page 342
Checking the transducer lower and hoist functionality - Sonar room steps, page 344
Summary of Contents for SC90
Page 2: ......
Page 16: ...14 419050 B Simrad SC90 ...
Page 219: ...419050 B 217 Øverland UPC 3005 Dimensions Cable layout and interconnections ...
Page 223: ...419050 B 221 Øverland UPC 5000P Dimensions Cable layout and interconnections ...
Page 438: ...436 419050 B 427177 Transducer dock dimensions page 494 Simrad SC90 Installation Manual ...
Page 441: ...419050 B 439 Drawing file ...
Page 442: ...440 419050 B Simrad SC90 Installation Manual ...
Page 445: ...419050 B 443 Drawing file ...
Page 452: ...450 419050 B Simrad SC90 Installation Manual ...
Page 455: ...419050 B 453 Drawing file ...
Page 458: ...456 419050 B Simrad SC90 Installation Manual ...
Page 463: ...419050 B 461 Drawing file ...
Page 468: ...466 419050 B Simrad SC90 Installation Manual ...
Page 469: ...419050 B 467 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 471: ...419050 B 469 Drawing file ...
Page 473: ...419050 B 471 214043 Gate valve installation DN350 Drawing file ...
Page 475: ...419050 B 473 422915 Gate valve installation DN350 Drawing file ...
Page 477: ...419050 B 475 083045 Gate valve installation DN500 Drawing file ...
Page 479: ...419050 B 477 33414 Gate valve dimensions DN350 Drawing file ...
Page 480: ...478 419050 B Simrad SC90 Installation Manual ...
Page 481: ...419050 B 479 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 482: ...480 419050 B 33473 Gate valve dimensions DN350 Simrad SC90 Installation Manual ...
Page 483: ...419050 B 481 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 484: ...482 419050 B 33498 Gate valve dimensions DN500 Simrad SC90 Installation Manual ...
Page 485: ...419050 B 483 Drawing file ...
Page 487: ...419050 B 485 37357 Gate valve dimensions DN500 Drawing file ...
Page 488: ...486 419050 B Simrad SC90 Installation Manual ...
Page 489: ...419050 B 487 Related topics Installing the optional gate valve DN500 page 103 Drawing file ...
Page 491: ...419050 B 489 Drawing file ...
Page 494: ...492 419050 B Simrad SC90 Installation Manual ...
Page 495: ...419050 B 493 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 497: ...419050 B 495 Drawing file ...
Page 542: ... 2018Kongsberg Maritime ISBN xxx ...
Page 543: ......
Page 544: ...Simrad SC90 Fish finding sonar Installation Manual ...