396
419050/B
•
Maximum transient
: 20% of nominal voltage, recovery time 3 s
•
Power consumption
: 600 VA (Approximately)
Power Supply Unit
•
Voltage requirement
: 230 VAC, 47 to 63 Hz, single phase, nominal
•
Maximum voltage deviation
: 15%
•
Maximum transient
: 20% of nominal voltage, recovery time 3 s
•
Power consumption
: 500 VA (Approximately)
Hull Unit SC90
•
Model
: SC90
•
Voltage requirement
: 230/380/440 VAC, 47 to 63 Hz, 3-phase
•
Maximum voltage deviation, 230 VAC
: 15%
•
Maximum voltage deviation, 380/440 VAC
: 340 - 485 VAC
•
Maximum transient
: 20% of nominal voltage, recovery time 3 s
•
Power consumption
: 3000 VA (Approximately)
Hull Unit SC94
•
Model
: SC94
•
Voltage requirement
: 230/380/440 VAC, 47 to 63 Hz, 3-phase
•
Maximum voltage deviation, 230 VAC
: 15%
•
Maximum voltage deviation, 380/440 VAC
: 340 - 485 VAC
•
Maximum transient
: 20% of nominal voltage, recovery time 3 s
•
Power consumption
: 3000 VA (Approximately)
Gate valve
The gate valve is not manufactured by Kongsberg Maritime. Refer to the relevant
end-user documentation provided by the manufacturer.
Related topics
Technical specifications, page 391
Simrad SC90 Installation Manual
Summary of Contents for SC90
Page 2: ......
Page 16: ...14 419050 B Simrad SC90 ...
Page 219: ...419050 B 217 Øverland UPC 3005 Dimensions Cable layout and interconnections ...
Page 223: ...419050 B 221 Øverland UPC 5000P Dimensions Cable layout and interconnections ...
Page 438: ...436 419050 B 427177 Transducer dock dimensions page 494 Simrad SC90 Installation Manual ...
Page 441: ...419050 B 439 Drawing file ...
Page 442: ...440 419050 B Simrad SC90 Installation Manual ...
Page 445: ...419050 B 443 Drawing file ...
Page 452: ...450 419050 B Simrad SC90 Installation Manual ...
Page 455: ...419050 B 453 Drawing file ...
Page 458: ...456 419050 B Simrad SC90 Installation Manual ...
Page 463: ...419050 B 461 Drawing file ...
Page 468: ...466 419050 B Simrad SC90 Installation Manual ...
Page 469: ...419050 B 467 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 471: ...419050 B 469 Drawing file ...
Page 473: ...419050 B 471 214043 Gate valve installation DN350 Drawing file ...
Page 475: ...419050 B 473 422915 Gate valve installation DN350 Drawing file ...
Page 477: ...419050 B 475 083045 Gate valve installation DN500 Drawing file ...
Page 479: ...419050 B 477 33414 Gate valve dimensions DN350 Drawing file ...
Page 480: ...478 419050 B Simrad SC90 Installation Manual ...
Page 481: ...419050 B 479 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 482: ...480 419050 B 33473 Gate valve dimensions DN350 Simrad SC90 Installation Manual ...
Page 483: ...419050 B 481 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 484: ...482 419050 B 33498 Gate valve dimensions DN500 Simrad SC90 Installation Manual ...
Page 485: ...419050 B 483 Drawing file ...
Page 487: ...419050 B 485 37357 Gate valve dimensions DN500 Drawing file ...
Page 488: ...486 419050 B Simrad SC90 Installation Manual ...
Page 489: ...419050 B 487 Related topics Installing the optional gate valve DN500 page 103 Drawing file ...
Page 491: ...419050 B 489 Drawing file ...
Page 494: ...492 419050 B Simrad SC90 Installation Manual ...
Page 495: ...419050 B 493 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 497: ...419050 B 495 Drawing file ...
Page 542: ... 2018Kongsberg Maritime ISBN xxx ...
Page 543: ......
Page 544: ...Simrad SC90 Fish finding sonar Installation Manual ...