Drawing file
165
851--164300 / C
Power to Hull Unit
This cable is used to connect AC power to the Motor Control Unit,
and thus also to the hull unit’s hoist motor. The drawing also
illustrates how to set up the motor connections to match the power
available.
W312
Revision: B
AC 3-phase power to Hull Unit
230 / 380 / 440 Vac
3-phase mains
Fused 10A slow
S301
in the Motor Control Unit
380 / 440 Vac
230 Vac
Motor
connections
U
V
W
GND
0
I
L1
1
L2
3
L3
5
T1
2
T2
4
T3
6
U1
V1
W1
GND
U1
V1
W1
GND
W2
W2
U2
U2
V2
V2
(824-112979/A)
Conductors
3 x 2.5 mm2
Screen
Seperate conductor, 2.5 mm2
Voltage
750 V
Max.diameter
17 mm