Simrad SP70
94
851-164336 / D
Upper
limit switch
S304
Brake
release
screw
Brake
release
screw
(not on SP75)
Hand crank
(No te th e groo v e in th e s h aft for
the fa s ten in g s c rew)
Hand crank
Lower
limit switch
S305
Motor
Control
Unit
Motor
Control
Unit
Note that the
gantries are not
drawn in scale.
SP70
SP71 / 72 / 73 / 74 / 75
(CD3421B)
Figure 32
Hand crank
12
Place the hand crank back into its storage position in the
Motor Control Unit.
13
Activate the hoisting contactor
K301
by setting the
hoisting/lowering switch
S302
to
Hoist
position, and check
if the contactor is deactivated when pressing the upper limit
switch
S304
upwards.
14
Activate the lowering contactor
K302
by setting the
hoisting/lowering switch
S302
to
Lower
position, and check
if the contactor is deactivated when pressing the lower limit
switch
S305
downwards.