Testing the peripheral equipment
131
851-164336 / D
13
Press
Close
to finish.
If you enter a wrong value and the sensor interface does not work,
you can change the parameters settings as many times as you wish.
The final settings you make are automatically saved when the
sonar system is switched off.
Serial line inspection
The Processor Unit contains an
Object Inspector
, where it is
possible to read the data of the connected serial line. This is a
valuable tool to check if the connections to the serial line are
working, and for checking the telegram format of the received
data.
Use the following procedure for viewing of the Object Inspector:
1
Select the
Setup
menu.
2
Presse
Test...
button to open the
System test
menu.
3
Press the
Message Bar
button, and observe the Message Bar
submenu appears ath the bottom of the menu field.
4
Select
Always on
in the submenu.
- Observe the appearance of a small horizontal bar at the
bottom of the display. On the right hand side of the bar,
a few buttons display the number of warnings, errors and
alarms that are given.
Figure 44 The Message
Bar submenu at the
bottom of the menu field
5
Double-click on the message bar line.with the
Object
button
on the Operator Panel, or with right mouse button.
6
Observe the
Object Inspector
appears.
Summary of Contents for Simrad SP70
Page 2: ......
Page 14: ...Simrad SP70 X 851 164336 D This page is intentionally left blank...
Page 62: ...Simrad SP70 46 851 164336 D Figure 13 Mounting the Transceiver Unit CD3110A...
Page 226: ...Simrad SP70 210 851 164336 D Party Date Signature Party Date Signature Party Date Signature...
Page 227: ......
Page 229: ......