SL 30/35 Hull Sonar Operators Manual
974-25007001/2.0
Menu and Software Description
Page 4.69
Kongsberg Simrad Mesotech Ltd.
Port Coquitlam, BC - Canada
messages. The contents of this file can be seen by using the System Messages Log Dialog
Box. This can be opened from the View Menu.
4.59.12
Factory Reset Settings
The Factory Reset settings are as follows:
Sector Train Heading
0
degrees
Sector Width
360
degrees
Step Size
X8
degrees
Range
100
meters
Gain
50
(40%)
Profiling
Disabled
XDCR Orientation
Up
Display Mode
HORIZONTAL
Telemetry Baud Rate
57600
Automatic pulse length selection enabled for maximum resolution
All overlay colors
RED.
Sector Display orientation
Up
Display Gain
100%
Grids
Enable
4.59.13
Gauge Windows: Customize
This dialog is used to customize gauge windows.