381295/B
131
2
Open the cabinet door.
WARNING
High voltages are used. This equipment must be serviced only by qualified
personnel familiar with high-voltage equipment and the potential hazards
involved. Failure to observe this precaution could result in bodily injury.
3
Locate the
Hoist/Lower Switch
(S302). Set the switch to position
STOP
.
This is for safety reasons.
4
Lowering the transducer:
a
Locate the
Lowering Contactor
(K302) on the right side.
b
Open the transparent plastic cover on the front of the contactor.
c
Use a small screw driver, and press the spring return actuator to apply voltage
to the motor.
d
Lower the transducer and STOP before you reach the bottom position.
5
Hoisting the transducer:
a
Locate the
Hoisting Contactor
(K301) on the left side.
b
Open the transparent plastic cover on the front of the contactor.
c
Use a small screw driver, and press the spring return actuator to apply voltage
to the motor.
d
Hoist the transducer and STOP before you reach the upper position.
6
Locate the
Hoist/Lower Switch
(S302). Set the switch to position
REMOTE
.
Note
For normal operation from the Operating Panel, the switch must be set to REMOTE.
7
Close the cabinet door.
Related topics