2200 PRO
2200 PRO
r
G een (Ground)
Neutral
Hot (120 6 Hz
V- 0
)
Jumper
2200-WM
WIND SENSOR
2200-LO
SUN SENSOR
120 VAC Connections
Low Voltage Connections
+
+
--
2400-RM
RAIN SENSOR
R
M
P
Ground (Green)
Hot Power L1 (Black)
Common N (White)
Motor
Power to Ind. Switch
Motor Direction (Red/Black)
Note: Connections are only at terminals
120 VAC Connections
Notice: For installation by a qualified
electrician in accordance with national
and local electrical codes.
T
erminals 6 through 13 are on Pro versions only
The 2200 control is for inside use only.
Do not install in an exposed location.
Terminals 1 thru 13 are low voltage. 18 gage wire
is acceptable for connections up to 100 feet.
Mount the wind sensor high enough and away
from obstructions to allow free wind flow past
the sensor.
Mount the sun sensor toward the direction of the
sun the window covering will be protecting from.
Make sure the sensor is not shaded by trees or
building structures. Do not mount the sun sensor
behind glass as this will reduce the sensitivity.
17
R
I3
N
N
CENTRAL
CENTRAL
N
N
N
N
L
L
POWER IN 115VAC
POWER IN 115VAC
GROUND
GROUND
5AMP MAX
5AMP MAX
N
P
M
INDIVIDUAL
SWITCH
P
M
INDIVIDUAL
SWITCH
P
M
INDIVIDUAL
SWITCH