SET
F
2200 PRO
2200 PRO
Press the set button (4) and the temperature threshold value will appear
(Fig. 9). You can adjust this value bu pressing the up (1) or down (3)
buttons.
Press the set button (4) to save the programmed temperature values
and return to the programming screen (Fig. 6). To adjust other values
see the following sections or press the stop button (2) to return to normal
operating mode.
6.3 Wind Function
- Enter the programming mode by pressing the set
button (4) for 3 seconds. The screen (Fig. 10) to the right will appear. Use
the up (1) or down (3) button to select the wind symbol (blinking)
Press the set button (4) and the wind speed threshold will appear
(Fig. 11). You can adjust this value up or down by pressing the up (1) or
down (3) buttons.
SET
M
M
Fig. 10
SET
mph
Fig. 11
Fig. 9
Press the set button (4) and the wind delay up time will appear (Fig. 12).
This is the time the wind speed must be above the wind threshold
before the 2200 raises the window covering. Normally this should be
kept low (2 to 3 sec.) You can adjust this value by pressing the up (1) or
down (3) buttons.
Press the set button (4) and the wind release time will appear (Fig. 13).
This is the time that must pass without a wind speed higher than the
wind threshold, before the 2200 will release the window covering. You
can adjust this value by pressing the up (1) or down (3) buttons.
Press the set button (4) and the wind test mode will appear (Fig. 14).
(See wind test section 7.1) Zero means the wind test is inactive. One
means the wind test is active. The mode can be changed by pressing
the up (1) or down (3) buttons.
Press the set button (4) to save the programmed wind values and return
to the programming screen (Fig. 10). To adjust other values see the
following sections or press the stop button (2) to return to normal
operating mode.
SET
sec
Fig. 12
SET
min
Fig. 13
SET
Fig. 14
7