EN
16/28
d3
: Possibility to program closing on cell-activation. This mode is only allowed with necessary security devices.
d4
: Shutter can close automatically after a dwell-time. This mode is only allowed with necessary security devices. In
this case, check
tA
in
t0
menu:
t0
TIMER PARAMETERS
Parameters
Value
Impulse 2BP
Mixed
Automatic
tF
Opening / closing timer
00
00
second to
4.0
minutes
1.0
1.0
30
tA
Re-closing timer
01
00
second to
4H00
10
10
05
tU
Warning timer before starting
02
00
second to
10
seconds
03
03
03
SETTING TIME
ta
PROCEDURE
Between 0 sec and 1 min press the button
or
to increase or decrease the timer by
1s
.
Between 1 min and 10 min press the button
or
to increase or decrease the timer by
5s
.
Between 10 min and 1 hour press the button
or
to increase or decrease the timer by
10 s
.
Between 1hour and 4 hour press the button
or
to increase or decrease the timer by
10 min
.
Summary of Contents for SIMUDRIVE SD510
Page 28: ...www simu com ...