EN
17/28
7.2 Input parameters
In the mixed mode, safety devices are not compulsory. As a result, input parameters can only be changed in expert
mode (chapter 4).
E0
INPUT PARAMETERS
Parameters
Value
Impulse 2BP
Mixed
Automatic
E1
Photocell 1 input
EXPERT MODE to modify
Safety input
on CLOSING
without self-test
with complete
reopening
Inactive
Safety input
on CLOSING
without self-test
with complete
reopening
E2
Photocell 2 input
EXPERT MODE to modify
Safety input
on CLOSING
without self-test
with complete
reopening
Inactive
Safety input
on CLOSING
without self-test
with complete
reopening
E3
8.2k safety edge
input configuration
00
Inactive
Programmed during 1st installation procedure
01
8.2k safety edge only
02
Air pressure safety edge without 8.2k
03
Air pressure safety edge with 8.2k
04
Pass-door function
E4
8.2k safety edge
function
01
Safety input on
CLOSING
with
COMPLETE
re-
opening
X
X
X
02
Safety input on
CLOSING
with
2 SECONDS
re-
opening
E5
OSE safety edge
function
00
Inactive
Programmed during 1st installation procedure
01
Safety input on
CLOSING
with
COMPLETE
re-
opening
02
Safety input on
CLOSING
with
2 SECONDS
re-
opening
E6
End limit type
00
Mechanical end limit
Programmed during 1st installation procedure
01
Electronic end limit
02
No end limit
EF
Radio channel
reaction during
opening
EXPERT MODE to modify
Reverse
EH
Function not used
EJ
Function not used
In the case of a shutter which can lift a person, the 5 safety accessories have to set like this :
•
Bottom photocells are connected on safety edge input : program E3 on 02 (air pressure safety edge without 8.2k).
• Top photocells are self-tested : program E1 and E2 on 04 (cf Chapter 4 to go in expert mode).
Summary of Contents for SIMUDRIVE SD510