EN
18/28
7.3 Output parameters
J0
OUTPUT PARAMETERS
Parameters
Value
Impulse 2BP
Mixed
Automatic
J1
High power output 1
function
00
Electric strike door release
01
Electromagnetic door lock
02
Brake contact NO
X
X
X
03
Brake contact NC
04
Flashing output
05
Door closed indication
J2
High power output 2
function
00
Electric strike door release
X
01
Electromagnetic door lock
02
Brake contact NO
03
Brake contact NC
04
Flashing output
X
X
05
Door closed indication
J3
Function not used
J5
Warning before starting
00
No warning before starting
01
Warning before start closing only
X
02
Warning before start opening and closing
X
X
J6
Low power output 1
function
00
Alarm
01
Timer
02
Door position
X
03
Self-test output NC
04
Self-test output NO
05
Automatic interlocking output
06
Buzzer output
07
Service point output
08
Service point deadman operating
09
Opened door indication
X
X
10
Closed door indication
11
Function not used
12
Function not used
JE
Red traffic lights flashing
configuration
EXPERT MODE to modify
Red lights are flashing on the two way
JF
Red light waiting
command configuration
EXPERT MODE to modify
Red lights are off during waiting command
phase
J2
: in impulse mode, change it in
04
to make the signaling light working.
8.1 Expert level activation
EXPERT LEVEL PARAMETERS
8
Summary of Contents for SIMUDRIVE SD510
Page 28: ...www simu com ...