1.5 Risk prevention
Risk areas : measures to be taken to eliminate risks
Installation which cannot lift a person or a child
Installation which could lift a person or a child
Areas to protect
Areas to protect
• Risk of crushing between the ground and the lower
edge of the door during closing.
Solution
:
• Obstacle detection using safety edge solution and
photocells.
Warning : in the case of not self-tested photocells,
they must be checked every 6 months.
• Risk of crushing between the ground and the lower
edge of the door during closing.
• Risk of jamming between the case and the door.
• Risk of jamming between guides and door.
Solution
:
• Photocells ( connection on not self-tested input to
check every 6 months )
• Obstacle detection on the top with self-tested
photocells.
DESCRIPTION OF SIMUDRIVE SD510 CONTROL BOX
2
2.1 Reference
DESIGNATION
REF.
SIMUDRIVE SD510
2008779
2.2 Technical datas
-
Three-phase supply :
• 230V 3~ 50/60Hz
• 380-415V 3N~ 50/60Hz
-
Maximum power : 1250W
-
Accessories power :
24Vdc / 0.5A - 230Vac / 250mA
-
Ambient working temperature:
+5°C +40°C
- Protection index: IP54
- Dimensions : 262 x 193 x 100 mm
- Weight : 3.2 kg
Summary of Contents for SIMUDRIVE SD510
Page 28: ...www simu com ...