EN
5/28
B1:
Motor encoder output (not used) , End limit contact.
B2:
3 command input (CMD1, CMD2, AUX) , Stop.
B3:
Safety edge inputs.
B4:
Photocell inputs and 24Vdc 20% / 0.5A global outputs.
B5:
Auxiliary outputs
Low power (dry contact). Switchable maximum current: 0.8A at 230Vac or 1.6A at 24Vdc.
2 auxiliary power outputs (dry contact). Maximum voltage and current for change-over switching: 400Vac / 1A
B6:
Power supply
B7:
Motor output
Led 1 & 2:
not used
Led 3:
Off if opening limit control input switch is activated
Led 4:
Off if closing limit control input switch is activated
Led 5:
Off if partial limit switch control input is activated
Led 6:
Off if pre-closing limit switch control input is activated
Led 7:
On if command 1 control input is activated
Led 8:
On if command 2 control input is activated
Led 9:
On if auxiliary control input is activated
Led 10:
Off if stop or emergency stop control input is activated
Led 11:
Off if photocell 1 control input is activated
Led 12:
Off if photocell 2 control input is activated
2.4 Description of external programming interface
Red light, error indicator or maintenance.
Blinks to indicate an error (see chapter 4, page 26).
Stay on to indicate the necessity of a maintenance.
To open the door.
To stop the door.
To close the door.
2.5 Compatibility and standard installation diagram
The SD510 control box has been designed to control the SIMU T9 and SIMUBOX three-phase motors as well as to be
used exclusively with the following SIMU accessories: OSE safety edge, cell barrier, reflex sensor, signalling light, SA Hz
standard re TSA + remote control, universal key box, unstable key box, inverters.
Summary of Contents for SIMUDRIVE SD510
Page 28: ...www simu com ...