AIR-TO-WATER HEAT PUMP INSTALLATION MANUAL
INDOOR UNIT
Model
Power Supply
V/Ph/Hz
380~415/3/50
Rated input (indoor only)
W
6200
Liquid side diameter
mm
(inch)
9.52(3/8)
Gas side diameter
mm
(inch)
15.9(5/8)
Cooling
(FCU)
℃
7-25
Cooling
(Floor )
℃
18-25
Heating
(FCU)
℃
25-55(High Temperature Cycle )
Operation Range
(Outflow water
temp.)
Heating
(Floor )
℃
25-45(Low Temperature Cycle )
Type -
Water-cooled
Nr. of speed
-
3
Power input
W
200
pump
Water flow
limit
LPM 7.5
Volume Liter
10
Water
Pressure
(Max)
Bar 3
Expansio
n Vessel
Water
Pressure
(Pre)
Bar 1
Type -
Sheath
Material -
Stainless
Steel
Operation -
Automatic
Steps -
1
Capacity 6
Combinatio
n
KW
6
Electric
Heater
Power input
Φ
/V/Hz
3/400/50
Type
-
Brazed Plate HEX
Mai
n
com
pon
ents
Heat
Exchange
r
Quantity -
1
Unit(W×D× H)
mm
900×500×324
Dim
ensi
ons
Packed unit(W×D× H)
mm
1040×605×380
21.2 Operation Range
Mode
Range of Outdoor Temperature(
℃
)
Heating -20~35
Cooling 10~48
Water heating
-20~45
GSH-12IRA-3
GSH-140IRA-3
GSH-160IRA-3
59
Summary of Contents for GSH-100ERA series
Page 2: ......
Page 49: ...AIR TO WATER HEAT PUMP INSTALLATION MANUAL GSH 120ERA 3 GSH 140ERA 3 GSH 160ERA 3 47 ...
Page 62: ......