Precaution for Use
• The display cases shall be used in proper environment with ambient temp.
<25
℃
, relative humidity<60%, higher temperature and humidity will
affect cabinet’s running.
• The leakage protection device must be installed and make sure to ground
adequately. Running voltage can be changed within AC 220V±10%
,
if the
voltage is unstable, choose stabilizer with proper capacity.
• Do not let cabinets close to heat source or under sunshine directly, around
passages and vent shall be closed to avoid damaging air curtain and
affecting refrigeration effect.
• It’s a normal phenomenon that when the cabinet is defrosting, the internal
temperature will rise in a short time.
• The needle type valve si used for system test and refrigerant filling-up, so
do not open it except professional people to prevent refrigerant leakage.
• Do not store inflammable, explosive, volatile fluid or gas.
• The shelves can stand not more tan20kg/m2, or the shelf may be
damaged.
• Put goods in and out carefully, do not throw goods to avoid damaging
cabinets.
• Reserve a certain place when arranging the foods, do not put foods in air
return, or it will affect air flow in cabinet and affect storages effect and
increase the energy consumption.
• Regularly change foods place according to the principle “first in, first out”
to avoid out –of-reach foods overdue or deterioration.
• Clean food scraps timely to avoid block defrosting drainage and lead to ice
clogging.
• Every foods has its shelf life, do not store it indefinitely.
• On the sake of clean, tidy and underlying, the foods shall be provided with
good package.
• Plug-in case has large tonnage, users shall discharge water at times.
• Have circuit inspection for temperature every 2 hours and record it.
Not: The leakage protection device must be tested once a mouth. Ask
professional people to maintain the cabinet if it is not running normally,
Before maintaining it, cut down the power source, also you must wear
security suits and use special tools.
Main Characteristics
•
Illumination
There are LEDs in the Cabinet, whose On and Off is controlled if you
need. It can be lighted when dark, also it can be closed when the light
sufficient or in non-business hours to reduce energy consumption. All the
illumination equipment adopt standard parts, so they can be changed if
they fails. Please cut off the power before changing, change it according