Page 5
List for maintenance and cleaning (content)
Interval
Location
Content, method and instruction for maintenance and
cleaning
Once/1-
3
months
accordi
ng
to real
conditio
ns
Beehive
net at
the air
discharge
Use clean and soft cloth dipped with neutral cleanser
to
clean beehive net surface dirt, then use clean water to
rinse
it, after air-drying, assemble it as before.
Note: if the air-dry not finished, do not run the
cabinet, or the ice scraps will block beehive net
holes.
Plug-in
compressi
ng
rack
Clean compressing rack completely, especially for
compressor, or it will down cabinet refrigerating speed,
decrease refrigerating capacity and increase internal
temperature long time no cleaning will lead to
compressor burned out.
Note: Do not let water on the fan motor, or it will
burned out
Once/2-
4
months
accordi
ng
to real
conditio
ns
Air return
net
Clean out food scraps and residues and remnant ice,
remove
air return net if necessary, special cleaning for those
places
we often omitted.
Note: Scraps and residues are agreed to take out,
not
allowed to rinse into drainage.
Condensin
g fan
Motor
Clean depositions on the condensing fan motor, if
necessary,
remove it to clean, and re-assemble according to the
opposite order. Do not let water on the fan motor.
Note:
Do not use polishing gaskets and agents, or it will damage the surface.
Do not use amino cleansers or corrosive cleansers, or it will damage
parts permanently
Do not let fluid touch e-parts.
Be sure to cut off the power source before cleaning.