Page 7
on the fan blades may cause faults of the motor.
• Check electrical equipment and parts regularly, Find and manage the
small problems in time to avoid serious accident.
• Keep the drainage clean and no scraps or its blockage will degrade
cooling capacity and damage the motors.
• Ammonia or amino detergents can damage electrical parts, so do not
use them.
• Check the adiabatic layer of the suction pipeline and repair its breakage,
to ensure pipeline adiabatic function.
• Make sure the load is appropriate, avoid use large posts in it, do not let
goods block or occupy the air channel. Put goods tidy and clean.
• If there has air flow with opposite direction compare with air curtain, it
will has unbenefited influence on cooling capacity, also too strong
lighting will affect its cooling capacity.
Note: Be sure to cut off the power source, use professional tools and wear
protecting clothes and gloves!
This equipment is intended for the storage and display of
non-potentiallyhazardous packaged products only