Socket Pin Function
1
Be shorted with 2
2
Be shorted with 1
3
20k ohm (maximum) connection
to 20k ohm remote control
potentiometer
4
Wiper arm connection to 20k ohm
remote control potentiometer
5
Zero ohm (minimum) connection
to 20k ohm remote control
potentiometer
6
Not connected
7
Not connected
8
Trigger Switch Input
9
Trigger Switch Input
10
Not connected
11
Not connected
12
Not connected
Trigger
Switch
Remote
Amps
max
min
complete. (Synchronization has to accomplish in
10s after the display is blank).
4. Switch the machine off and back on again to start
welding operation.
5. If the operation is unsuccessful, repeat steps 1 to 4.
6. During operation, the front panel control on the
power supply is still functional but the remote
control panel or foot pedal has higher priority
level.
7. When the remote control panel or foot pedal is
idles for 10 seconds, it will automatically go into
“sleep” mode.
8. Only front Panel Control is active when wireless
remote control or foot pedal is in “sleep” mode.
Any operation on the wireless remote control
panel or foot pedal will “wake it up and resumes
control of the machine.
6.5.2. Wire foot pedal Configuration
•
When plug the twelve-lead aero-socket of pedal
switch in it. Welder will identify the pedal switch,
the welding current knob on the front panel will
can’t use and only 2T can be selected.
•
When use the adjustment knob of max-welding
current beside the pedal, can set the max-current
you want.
28
1.995.229 EN - Rev. 1.1