22
Singer Furtura III series
17. Retaining bracket for bobbin case
Check
1. Remove needle plate and bobbin case.
2. Check so the corner of plate spring aligns with inside of wall (A) of shuttle race .
3. Insert the bobbin case.
4. Turn the bobbin case clockwise until it hits the reverse rotation stopper.
5. It should now be a distance of 1 to 1.5 mm between the projection of the bobbin case and plate
spring.
Adjustment
1. Loosen screw (B).
2. Move the retaining bracket (E) so the corner of plate spring aligns with inside of wall (A) of shuttle
race.
3. Tighten the screw (B).
4. Insert the bobbin case.
5. Loosen screw (C) and adjust the position of reverse rotation stopper (F) so that there is a clearance
of 1 to 1.5 mm between the projection and plate spring while turning the bobbin case back and forth.
6. Tighten the screw (C) securely.
1-1.5 mm
C
F
A
B
C
E
F
E
B