Additional sheet
62
Ⅱ
. Trouble shooting and handling:
Troubleshooting of Grating Ruler and Digital display Meter
The following troubleshooting is primary only. If there are still problems,
do not dismantle them by yourself, seek help from our company or
corresponding agents.
Symptom of
failure
Source of failure
Troubleshooting
Digital
display
meter does
not display
1. Is it connected to power
supply?
1. Check power wire, then
switch on power supply.
2. Is power switch closed?
2. Close the power switch.
3. Is appropriate mains voltage
used?
3. Mains voltage should be
within 60~260V.
4. Shorting of power supply
inside grating ruler.
4. Disconnect plug of grating
ruler.
Enclosure
of digital
display
meter is
charged.
1. Is enclosure of machine tool
and digital display meter well
grounded?
1. Well ground enclosure of
machine tool and digital
display meter
2. Is there electric leakage from
220V power supply to the
ground?
2. Check 220V power supply.
One axis of
digital
display
meter does
not count.
1. Exchange with the grating
ruler on the other axis, and
then operate to see if it no
longer counts.
1. If counting is normal failure
of grating ruler.
If counting is abnormal failure
of digital display meter.
2. Is digital display meter in
some special function?
2. Exit special function.
Summary of Contents for SDS2MS
Page 4: ...Illustration of Panel and Keyboard 1...
Page 21: ...B Smooth R 13 B Smooth R Iran agent Tel 021 66 3939 00 Mob 0912 147 3023 www Sino ir...
Page 30: ...C Simple R 22 C Simple R Iran agent Tel 021 66 3939 00 Mob 0912 147 3023 www Sino ir...
Page 65: ...J N3 Function 57 J N3 Function Iran agent Tel 021 66 3939 00 Mob 0912 147 3023 www Sino ir...