TH1310WF

Installation Guide

Smart floor heating 

thermostat (3600 W)

3) The thermostat offers 2 temperature regulation modes:
F mode (default):

 Regulates the floor temperature by means of an 

external temperature sensor with the possibility to limit ambient 

temperature.

A mode: 

Regulates ambient temperature with the possibility to limit floor 

temperature by means of an external temperature sensor.  

4) Maximum limit of the ambient temperature (F mode)

Thermostat limits floor heating so as not to exceed the set ambient 

temperature limit 

5) Maximum floor temperature limit (A mode) 

The thermostat limits floor heating to the set temperature to ensure it does 

not exceed the selected limit. Ideal for protecting engineered wood floors.

6) Minimum floor temperature limit (A mode)

The thermostat limits the minimum temperature of the floor in order to 

keep it at a comfortable temperature. 

This parameter can only be used when a floor sensor is connected to the 

thermostat. 

7) Assigning the auxiliary output (A mode):  

The thermostat provides an auxiliary output that has three functions which 

are set from the user settings. 

15 sec function: 

Short cycle auxiliary output (15 seconds). Used for a heater 

controlled through an electronic relay (SSR). 

15 min function: 

Long cycle auxiliary output (15 minutes). 

 Used for a heater 

controlled through an electromechanical relay or equipped with a fan. 

In the 15 sec and 15 min functions,

 

the thermostat controls the ambient 

temperature with the floor. Once the floor temperature has reached its 

limit, if the desired ambient temperature is not reached, the auxiliary output 

activates the heating device to reach the set temperature. (The auxiliary 

output acts as a second heating stage.)

EXP function: 

 Auxiliary output to connect several heating floors 

(TR1310 sold separately).

OFF function (default):

 Disables the auxiliary output.

INSTALL YOUR THERMOSTAT

Unlock and lift the thermostat 

cover.

Warnings 

Before starting the installation of your new thermostat, please 

make sure that the breakers for your heating system are off at 

the main electrical panel!

The installation of this thermostat must be performed by a 

certified electrician and comply with the national and local 

electrical codes and regulations.

Line

Load

Floor heating

1

Connect the sensor.

(Only for control applications in 

F mode or with floor limit.)

3

Connect the heating floor by using the 

wire connectors load / line located on 

the back of the thermostat. Connect the 

ground wire to the screw in the 

electrical box intended for this purpose.

2

Use the screws to secure 

the thermostat to the 

electrical box.

4

Replace the cover and lock.

5

Power up the thermostat.

After performing a test sequence, 

the thermostat should display the 

floor temperature. If not, refer to 

the trouble- shooting guide in 

this manual.

6

Sensor

USER SETTINGS 

Increasing or lowering the temperature 

To adjust the temperature, press       or      . The requested temperature 

will blink to confirm the new setpoint.

Get the setpoint to its minimum and hold the       button for 10 seconds 

to access the menu.

Press the       or       button to change the setting. 

All of the thermostat's settings can be set through the Neviweb app. 

However, if you have not created your account and wish to change the 

temperature format or the control cycle, you need to: 

The following table lists the settings that can be changed directly on 

the thermostat.

You can change more settings through the Neviweb application.

10 sec.

Press the      and      buttons simultaneously to save and go 

to the next parameter. Continue to press until the end of the 

list to exit the menu.

USER SETTINGS 

 (continued)

Settings which can be modified directly on the device:

Control 

Load

Display

Max Floor

Max Air

Min Floor

Aux

Sensor

Load power

0 watt to 3600 watt

Temperature format

°C or °F (default: °C)

Control mode

A (Air), F (Floor) (default: F)

Maximum floor temperature

(Only visible in A mode)

5 °C to 36 °C (default: OFF)

Maximum limit of the ambient

(Only visible in F mode)

5 °C to 36 °C (default: OFF)

Minimum floor temperature limit

(Only visible in A mode)

5 °C to 36 °C (default: OFF)

Floor sensor

10K or 12K (default: 10K)

Assignment of auxiliary output

OFF, EXP, 15 sec, 15 min (default: OFF)

Name

Parameters & settings

Display

** To disconnect a thermostat from a network, refer to the disconnection  

    procedure on the back of this guide.

When installing your floor heating system: add a second 

sensor in the floor whose tip can be stored in the 

thermostat housing. This additional sensor can be 

plugged in and used as a replacement without 

altering your floor heating system.

Sensor

Leaving the standby mode

When the thermostat is on standby, press any button to turn back ON the 

thermostat. The thermostat will resume operation under its last program 

settings. 

A thermostat that is placed on standby before a power failure will be on 

standby by default when power is restored.

7
8