background image

The thermostat is equipped with a ground fault protection that can 

detect a current leakage of 5 mA. When a current leakage is detected, 

the ground fault protection is triggered and quickly interrupts the power 

supply to prevent any serious injuries.

Resetting the ground fault protection 

The RESET button warning light turns ON (red) when the ground 

fault protection is triggered. If the RESET button warning light turns 

ON during normal operation of the thermostat, simply press the 

RESET button to reset the ground fault protection. The light will turn 

OFF. If for any reason this situation occurs again, cut the power to 

the heating system from the main electrical panel and ask a 

qualified electrician to verify the installation. 

Testing the ground fault protection 

This thermostat has an Auto Test which periodically verifies the 

correct operation of the protection circuit. You can also do this 

manually:
1) Press the TEST button. If the RESET button's, red warning light does 

not turn ON, the test has failed. Cut the power to the heating system 

from the main electrical panel and ask a qualified electrician to verify 

the installation. 
2) Press the RESET button to restart the thermostat's base. 

TROUBLESHOOTING GUIDE

What should I do if the E1F code appears on 

my thermostat display?

The E1F code means that the thermostat is in 

“Floor” mode and there is no connected 

sensor. If your thermostat is not intended to 

control an heated floor, change the 

thermostat’s control mode for the “A mode”.

Use of the Works with Apple badge means that an accessory has been designed to work 

specifically with the technology identified in the badge and has been certified by the 

developer to meet Apple performance standards. Apple is not responsible for the operation 

of this device or its compliance with safety and regulatory standards.

HomeKit is a trademark of Apple Inc.

Neviweb® is a registered trademark of Sinopé Technologies Inc. in Canada and the United 

States.

Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other 

countries.

App Store is a service mark of Apple Inc., registered in the U.S. and other countries. Google 

Play and the Google Play logo are trademarks of Google Inc.

The Wi-Fi CERTIFIED™ Logo is a certification mark of Wi-Fi Alliance®

For more information, visit our Website:

Trasmitter module IC: 21098-ESPWROOM32 / FCC ID: 2AC7Z-ESPWROOM32

This device complies with Industry Canada license exempt RSS standard(s). Operation is subject to the 

following two conditions: 

(1) this device does not cause interference, and (2) this device must accept any interference, including 

interference that may cause undesired operation of the device.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant 

to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 

interference in a residential installation. This equipment generates, uses and can radiate radio frequency 

energy, and if not installed and used in accordance with the instructions, may cause harmful interference 

to radio communications. However, there is no guarantee that interference will not occur in a particular 

installation. If this equipment does cause harmful interference to radio or television reception, which can 

be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the 

interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

3-year limited warranty

SINOPE TECHNOLOGIE INC. warrants the components of their products against 

defects in material and workmanship for a 3-year period from the date of purchase, 

under normal use and service, when proof of purchase of such is provided to the 

manufacturer. This warranty does not cover any transportation costs that may be 

incurred by the consumer. Nor does it cover a product subjected to misuse or 

accidental damage. The obligation of SINOPÉ TECHNOLOGIE INC., under the terms 

of this warranty, will be to supply a new unit and this releases the manufacturer from 

paying the installation costs or other secondary charges linked to replacing the unit 

or the components.

660-0735-0024-B

PROTECTION CONTRE LES FUITES À LA TERRE

TECHNICAL SPECIFICATIONS

Controlling this HomeKit-enabled accessory automatically and 
away from home requires a HomePod, Apple TV, or iPad set 
up as a home hub. It is recommended that you update to the 
latest software and operating system.

GROUND FAULT PROTECTION 

10 sec.

CONNECT AN EXPANSION UNIT (TR1310)         

CONNECT THE AUXILIARY OUTPUT 

It is possible to connect up to 10 expansion units to the 

same device. (EXP function)

Second heating stage (15 sec / 15 min functions)

TR1310

TR1310

To others
TR1310

TH1310WF

24 VCA

Baseboard

Convector

Transformer

CONNECT YOUR THERMOSTAT TO YOUR APPLICATION

Tap the       then select "Add Device"

2

1

If you do not have an account yet, 

download the Neviweb app for iOS or 

Android to open an account and add 

your device.

Follow the steps of the Installation Wizard

3

To disconnect your thermostat from the Wi-Fi router press the    

      and       buttons simultaneously for 10 seconds. The      symbol 

will disappear from the display. 

To remove your thermostat from Neviweb, press Delete in 

the thermostat settings.

DISCONNECT YOUR THERMOSTAT FROM THE 

WI-FI ROUTER OR THE NEVIWEB APP

Operating voltage: 

120/208/240 Vac, 50/60 Hz

Maximum load: 

1800 W @ 120 V / 15 A 

3120 W @ 208 V / 15 A 

3600 W@ 240 V/ 15 A

Setpoint range: 

5 °C to 36 °C (41 °F to 96 °F) 

Display range: 

0 °C to 50 °C (32 °F to 99 °F) 

Resolution: 

±

 0.5 °C (

±

 1 °F) 

Storage: 

-20 °C to 50 °C (-4 °F to 122 °F)

Auxiliary output: 

24 Vac/Vdc / 0.1 A 

GFCI protection:

 Class A (5mA)

Protocole : 

Wi-Fi

Standard: 

IEEE 802.11 b/g/n

Frequency: 

2.4 GHz

Reviews: